Mapping of cerebral metabolite concentrations in brain tumors using 1H-MRSI and quantitative MRI

Motivation: Absolute quantification of the 1H MRS metabolites remains a challenge for 2D MRSI, due to long acquisition times for the unsuppressed water reference and the multiple biases present due to relaxation and inhomogeneity. Goal(s): To propose a water reference method combining single voxel STEAM and quantitative MRI (qMRI). Approach: The method is demonstrated and tested against a standard water referencing method on one healthy subject. Its application is demonstrated in a brain tumor patient. Results: Apart from obtaining absolute metabolite concentrations, corrected for all water relaxation times, 4 qMRI maps (PD, T1, T2* and QSM) maps are also generated. Impact: We propose a method for absolute quantification of cerebral metabolites in 2D MRSI by combining STEAM and quantitative MRI. The method is tested against a reference method in a healthy subject and its application demonstrated for a brain tumor patient.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/1829
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mapping of cerebral metabolite concentrations in brain tumors using 1H-MRSI and quantitative MRI

Dennis R. Thomas, А. В. Манжурцев, Katharina J. Wenger, Ulrich Pilatus et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Medical Imaging Techniques and Applications
article

Mapping of cerebral metabolite concentrations in brain tumors using 1H-MRSI and quantitative MRI

Dennis R. Thomas, А. В. Манжурцев, Katharina J. Wenger, Ulrich Pilatus, Elke Hattingen, Şeyma Alçiçek
article en

Abstract

Motivation: Absolute quantification of the 1H MRS metabolites remains a challenge for 2D MRSI, due to long acquisition times for the unsuppressed water reference and the multiple biases present due to relaxation and inhomogeneity. Goal(s): To propose a water reference method combining single voxel STEAM and quantitative MRI (qMRI). Approach: The method is demonstrated and tested against a standard water referencing method on one healthy subject. Its application is demonstrated in a brain tumor patient. Results: Apart from obtaining absolute metabolite concentrations, corrected for all water relaxation times, 4 qMRI maps (PD, T1, T2* and QSM) maps are also generated. Impact: We propose a method for absolute quantification of cerebral metabolites in 2D MRSI by combining STEAM and quantitative MRI. The method is tested against a reference method in a healthy subject and its application demonstrated for a brain tumor patient.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 64%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.