Pushing contrast at low field with very high B1

Motivation: Inherently reduced SAR at low B0 fields opens the possibility for sequences employing high B1 to generate contrasts inaccessible on common systems. Goal(s): Explore generation of magnetization transfer (MT) and inhomogeneous MT (ihMT) contrast using high B1 sequences on low-field MRI system. Approach: A tuned resonator was used to enhance B1 fields locally within a 0.55T scanner. Rapid gradient-echo based MT/ihMT sequences were tested on ex-vivo lamb brain sample. Results: Achieved ~9-fold increase in B1, boosting observed MTR/ihMTR. Unexpectedly, RF pulses failed to function at high B1 due to Bloch-Siegert and spin-locking; new pulse designs for this regime will form future work. Impact: Using high B1 fields at low B0 enables contrasts that were previously off-limits due to safety constraints at high B0. To exploit these with clinical hardware we demonstrate a passive resonator that increases the B1 by a factor of 9.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0960
Primary Topic
Optical Systems and Laser Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pushing contrast at low field with very high B1

Daniel W. D. West, Shaihan Malik, Özlem İpek, Tobias Wood et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Optical Systems and Laser Technology
article

Pushing contrast at low field with very high B1

Daniel W. D. West, Shaihan Malik, Özlem İpek, Tobias Wood, Joseph V. Hajnal, David Leitão, Avanya Prathapan
article en

Abstract

Motivation: Inherently reduced SAR at low B0 fields opens the possibility for sequences employing high B1 to generate contrasts inaccessible on common systems. Goal(s): Explore generation of magnetization transfer (MT) and inhomogeneous MT (ihMT) contrast using high B1 sequences on low-field MRI system. Approach: A tuned resonator was used to enhance B1 fields locally within a 0.55T scanner. Rapid gradient-echo based MT/ihMT sequences were tested on ex-vivo lamb brain sample. Results: Achieved ~9-fold increase in B1, boosting observed MTR/ihMTR. Unexpectedly, RF pulses failed to function at high B1 due to Bloch-Siegert and spin-locking; new pulse designs for this regime will form future work. Impact: Using high B1 fields at low B0 enables contrasts that were previously off-limits due to safety constraints at high B0. To exploit these with clinical hardware we demonstrate a passive resonator that increases the B1 by a factor of 9.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 81%
Optical Systems and Laser Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.