Radio-Frequency Energy-Induced Heating for hot spots with the same SAR averaged over 0.1 gram without perfusion

Motivation: Evaluating induced temperature rise (ΔT) in human tissue at a hot spot. Goal(s): Comprehensive analysis of ΔT by examining cases where SAR0.1 g (SAR, specifically averaged over a mass of 0.1 gram of human tissue) remains constant but the spatial distribution of SAR inside and outside the averaging volume is different. Approach: Analytical solutions were obtained for estimating ΔT as a result of the SAR distribution exhibiting spherical symmetry with both uniform and Gaussian distributions. Results: Using SAR0.1g without consideration of the distribution of SAR within and outside the enclosed volume cannot be a reliable tool for estimation of ΔT. Impact: We have obtained analytical results on the effect of the SAR distribution on the conservatively estimated ΔT in different RF exposure scenarios.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3732
Primary Topic
Energy Harvesting in Wireless Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radio-Frequency Energy-Induced Heating for hot spots with the same SAR averaged over 0.1 gram without perfusion

Nicolas Boulant, Mikhail Kozlov
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Energy Harvesting in Wireless Networks
article

Radio-Frequency Energy-Induced Heating for hot spots with the same SAR averaged over 0.1 gram without perfusion

Nicolas Boulant, Mikhail Kozlov
article en

Abstract

Motivation: Evaluating induced temperature rise (ΔT) in human tissue at a hot spot. Goal(s): Comprehensive analysis of ΔT by examining cases where SAR0.1 g (SAR, specifically averaged over a mass of 0.1 gram of human tissue) remains constant but the spatial distribution of SAR inside and outside the averaging volume is different. Approach: Analytical solutions were obtained for estimating ΔT as a result of the SAR distribution exhibiting spherical symmetry with both uniform and Gaussian distributions. Results: Using SAR0.1g without consideration of the distribution of SAR within and outside the enclosed volume cannot be a reliable tool for estimation of ΔT. Impact: We have obtained analytical results on the effect of the SAR distribution on the conservatively estimated ΔT in different RF exposure scenarios.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Affordable and clean energy
Openalex Percentile: Top 81%
Energy Harvesting in Wireless Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.