31P MRSI multi-channel signal combination using 23Na coil sensitivity profiles at 7T: further evaluations in silico, on phantom, and in vivo

Motivation: Multi-channel 31P MRSI signal combination is challenging due to low intrinsic SNR. Goal(s): Improve multi-channel 31P signal combination for a multi-tuned 31P/23Na head coil receiver array. Approach: Combining 15-channel 31P data using the 23Na sensitivity maps received with the same dual-tuned array. The results are evaluated quantitatively and qualitatively in silico, on phantom scans, and in vivo. Results: Simulation shows <5% SNR-decrease by combining 31P signals using 23Na sensitivities. Phantom data shows 25% SNR-decrease but also potential for mitigating point-spreading effect. In vivo data analysis shows 5% SNR increase when the intrinsic SNR is low but 15% decrease after the dataset is denoised. Impact: This study explores an alternative approach for multi-channel 31P MRSI signal combination. The performance is positive when intrinsic SNR is low. This approach can be extended to other X-nuclei with not-too-far Larmor frequencies if multi-tuned receiver antennas are used.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/1913
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

31P MRSI multi-channel signal combination using 23Na coil sensitivity profiles at 7T: further evaluations in silico, on phantom, and in vivo

Dennis W. J. Klomp, Mark Gosselink, Alexander Raaijmakers, Jiying Dai
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

31P MRSI multi-channel signal combination using 23Na coil sensitivity profiles at 7T: further evaluations in silico, on phantom, and in vivo

Dennis W. J. Klomp, Mark Gosselink, Alexander Raaijmakers, Jiying Dai
article en

Abstract

Motivation: Multi-channel 31P MRSI signal combination is challenging due to low intrinsic SNR. Goal(s): Improve multi-channel 31P signal combination for a multi-tuned 31P/23Na head coil receiver array. Approach: Combining 15-channel 31P data using the 23Na sensitivity maps received with the same dual-tuned array. The results are evaluated quantitatively and qualitatively in silico, on phantom scans, and in vivo. Results: Simulation shows <5% SNR-decrease by combining 31P signals using 23Na sensitivities. Phantom data shows 25% SNR-decrease but also potential for mitigating point-spreading effect. In vivo data analysis shows 5% SNR increase when the intrinsic SNR is low but 15% decrease after the dataset is denoised. Impact: This study explores an alternative approach for multi-channel 31P MRSI signal combination. The performance is positive when intrinsic SNR is low. This approach can be extended to other X-nuclei with not-too-far Larmor frequencies if multi-tuned receiver antennas are used.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

31P MRSI multi-channel signal combination using 23Na coil sensitivity profiles at 7T: further evaluations in silico, on phantom, and in vivo — Dennis W. J. Klomp, Mark Gosselink, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS