Cardiac and respiratory self-gating based on PCA of selected points from coil arrays

Motivation: ECG-gating for cardiac MR Imaging may fail, especially at high field, and the conventional self-gating method is insufficient to effectively extract the cardiac signal in 3D cardiac MR cine with high precision (previous precision 20-30ms). Goal(s): Our goal was to achieved a reliable cardiac self-gating technique with the precision of 10ms level. Approach: We proposed a two-step selective PCA self-gating method by first selecting the heart beating or respiration sensitive points and then performing PCA. Results: The proposed method achieved a temporal precision of 11ms for 3D cardiac cine images. Impact: The proposed selective PCA self-gating technique can be applied in poor ECG-gating MR scans, such as patients with hairy chests or obesity, as well as in high-field environments, with a high level of precision down to 11ms.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/1639
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cardiac and respiratory self-gating based on PCA of selected points from coil arrays

Rongzhen Ouyang, Liwei Hu, Peng Hu, Yumin Zhong et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Non-Invasive Vital Sign Monitoring
article

Cardiac and respiratory self-gating based on PCA of selected points from coil arrays

Rongzhen Ouyang, Liwei Hu, Peng Hu, Yumin Zhong, Wenjian Liu, Wenchao Yang, Haikun Qi, Dong Wang
article en

Abstract

Motivation: ECG-gating for cardiac MR Imaging may fail, especially at high field, and the conventional self-gating method is insufficient to effectively extract the cardiac signal in 3D cardiac MR cine with high precision (previous precision 20-30ms). Goal(s): Our goal was to achieved a reliable cardiac self-gating technique with the precision of 10ms level. Approach: We proposed a two-step selective PCA self-gating method by first selecting the heart beating or respiration sensitive points and then performing PCA. Results: The proposed method achieved a temporal precision of 11ms for 3D cardiac cine images. Impact: The proposed selective PCA self-gating technique can be applied in poor ECG-gating MR scans, such as patients with hairy chests or obesity, as well as in high-field environments, with a high level of precision down to 11ms.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
No poverty
Openalex Percentile: Top 80%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.