Deep-learning-based flow-artifact correction for multi-shot multiple overlapping-echo detachment imaging (msh-MOLED)

Motivation: Multi-shot overlapping-echo detachment imaging (msh-MOLED), a msh-EPI-based quantitative MR sequence, quantifies tissue T2 rapidly without the need of separately acquiring images with different TEs, but its results could be contaminated by flow-induced inter-shot phase variations. Goal(s): To implement an instantaneous referenceless flow-artifact correction for msh-MOLED. Approach: Flow-related features were added to the training data, and the trained network fulfilled T2 mapping free from flow artifacts without dear computational costs or additional reference data. Results: After correction, the Pearson’s correlation coefficient/mean absolute error was changed from 0.6332/6.5328 (uncorrected) to 0.8808/2.7623 (corrected). Impact: The proposed correction could be used to retain the mapping accuracy of msh-MOLED regardless of shot numbers, or to refine the reference data in high-spatial-resolution diffusion mapping potentially.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/5002
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep-learning-based flow-artifact correction for multi-shot multiple overlapping-echo detachment imaging (msh-MOLED)

Liangjie Lin, Shuhui Cai, Congbo Cai, Qizhi Yang et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Deep-learning-based flow-artifact correction for multi-shot multiple overlapping-echo detachment imaging (msh-MOLED)

Liangjie Lin, Shuhui Cai, Congbo Cai, Qizhi Yang, Jianfeng Bao, Zhong Chen, Ming Ye, Ying Lin
article en

Abstract

Motivation: Multi-shot overlapping-echo detachment imaging (msh-MOLED), a msh-EPI-based quantitative MR sequence, quantifies tissue T2 rapidly without the need of separately acquiring images with different TEs, but its results could be contaminated by flow-induced inter-shot phase variations. Goal(s): To implement an instantaneous referenceless flow-artifact correction for msh-MOLED. Approach: Flow-related features were added to the training data, and the trained network fulfilled T2 mapping free from flow artifacts without dear computational costs or additional reference data. Results: After correction, the Pearson’s correlation coefficient/mean absolute error was changed from 0.6332/6.5328 (uncorrected) to 0.8808/2.7623 (corrected). Impact: The proposed correction could be used to retain the mapping accuracy of msh-MOLED regardless of shot numbers, or to refine the reference data in high-spatial-resolution diffusion mapping potentially.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.