Rapid Method for Chemical Shift Saturation Recovery (CSSR) Acquisition with 129Xe MR

Motivation: Hyperpolarized 129Xe Chemical Shift Saturation Recovery (CSSR), commonly employed for assessing pulmonary physiological function, is time-consuming and prone to weak signals and potential errors at short exchange times. Goal(s): To accelerate the acquisition of CSSR while ensuring the precise physiological parameter extraction. Approach: Techniques of inversion recovery (IR) and look-locker (LL) were combined with conventional CSSR (refer to as IR-LL-CSSR), and the results were compared with that obtained by conventional CSSR and IR-CSSR. Results: By using the proposed method (IR-LL-CSSR), the acquisition could be accelerated for eight times, and meanwhile preserve the accuracy of the extracted physiological parameters. Impact: IR-LL-CSSR substantially accelerates CSSR acquisition with 129Xe MRS and also ensures a precise physiological parameter assessment, showing promise for improving the pulmonary assessment in clinic.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4729
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Method for Chemical Shift Saturation Recovery (CSSR) Acquisition with 129Xe MR

Hongchuang Li, Xiaoling Liu, Ming Zhang, Haidong Li et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Atomic and Subatomic Physics Research
article

Rapid Method for Chemical Shift Saturation Recovery (CSSR) Acquisition with 129Xe MR

Hongchuang Li, Xiaoling Liu, Ming Zhang, Haidong Li, Xin Zhou, Yu Zheng, Xiuchao Zhao, Yeqing Han
article en

Abstract

Motivation: Hyperpolarized 129Xe Chemical Shift Saturation Recovery (CSSR), commonly employed for assessing pulmonary physiological function, is time-consuming and prone to weak signals and potential errors at short exchange times. Goal(s): To accelerate the acquisition of CSSR while ensuring the precise physiological parameter extraction. Approach: Techniques of inversion recovery (IR) and look-locker (LL) were combined with conventional CSSR (refer to as IR-LL-CSSR), and the results were compared with that obtained by conventional CSSR and IR-CSSR. Results: By using the proposed method (IR-LL-CSSR), the acquisition could be accelerated for eight times, and meanwhile preserve the accuracy of the extracted physiological parameters. Impact: IR-LL-CSSR substantially accelerates CSSR acquisition with 129Xe MRS and also ensures a precise physiological parameter assessment, showing promise for improving the pulmonary assessment in clinic.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 81%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.