Motion compensated SE diffusion tensor cardiovascular magnetic resonance at ultra-high gradient strength at Connectom scanner

Motivation: Second-order motion-compensated spin-echo (MCSE) DT-CMR is limited by long echo-times (TE), resulting in T2-related signal-loss. Goal(s): Use the ultrahigh gradient-strength of the Connectom scanner to reduce TE of second-order MCSE DT-CMR. Approach: A second-order MCSE DT-CMR pulse-sequence was developed. Ultra-high (180mT/m) and a high gradient-strength (80mT/m) were compared in acquiring in-vivo DT-CMR data at two cardiac phases. Results: The substantial reduction in TE enabled by ultra-high gradient-strength resulted in improvements in signal-to-noise ratio (SNR) in both cardiac phases. To our knowledge this is the first report comparing the performance of second-order MCSE DT-CMR at ultra-high gradient-strength (Connectom) to widely available high gradient-strengths. Impact: Second-order MCSE DT-CMR acquired using ultra-high diffusion gradient strengths increases SNR in both cardiac phases, paving the way for future clinical translation of efficient multiphase DT-CMR.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3919
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Motion compensated SE diffusion tensor cardiovascular magnetic resonance at ultra-high gradient strength at Connectom scanner

Andrew D. Scott, Camila Escobar, John R. Evans, Sònia Nielles‐Vallespin et al.
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Motion compensated SE diffusion tensor cardiovascular magnetic resonance at ultra-high gradient strength at Connectom scanner

Andrew D. Scott, Camila Escobar, John R. Evans, Sònia Nielles‐Vallespin, Fabrizio Fasano, Dudley J. Pennell, Pedro Ferreira, Shubhajit Paul
article en

Abstract

Motivation: Second-order motion-compensated spin-echo (MCSE) DT-CMR is limited by long echo-times (TE), resulting in T2-related signal-loss. Goal(s): Use the ultrahigh gradient-strength of the Connectom scanner to reduce TE of second-order MCSE DT-CMR. Approach: A second-order MCSE DT-CMR pulse-sequence was developed. Ultra-high (180mT/m) and a high gradient-strength (80mT/m) were compared in acquiring in-vivo DT-CMR data at two cardiac phases. Results: The substantial reduction in TE enabled by ultra-high gradient-strength resulted in improvements in signal-to-noise ratio (SNR) in both cardiac phases. To our knowledge this is the first report comparing the performance of second-order MCSE DT-CMR at ultra-high gradient-strength (Connectom) to widely available high gradient-strengths. Impact: Second-order MCSE DT-CMR acquired using ultra-high diffusion gradient strengths increases SNR in both cardiac phases, paving the way for future clinical translation of efficient multiphase DT-CMR.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Affordable and clean energy
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.