Non-Contrast MR Perfusion Imaging of the Hip
Motivation: Avascular necrosis of the hip is due to disturbed blood supply related to various causes. Early evaluation currently requires contrast enhanced MR perfusion imaging. Goal(s): Evaluate human hip perfusion using non-contrast MR perfusion technique. Approach: Bilateral hips of healthy volunteers were imaged coronally at 3-T using a 2D spin labeling MR perfusion technique using tag-on tag-off acquisition at varying TI and processing to determine tagged blood signal into the acetabulum, femoral head, and femoral neck. Results: We found distinct perfusion signal in the acetabulum but the signal in the femoral head and neck were more subdued. Impact: This study demonstrates the feasibility of non-contrast MR perfusion imaging of the human hip, with future application in evaluation of avascular necrosis.
Authors
- Won C. Bae (ORCID: https://orcid.org/0000-0003-2616-0339)
- Vadim Malis (ORCID: https://orcid.org/0000-0002-0426-1457)
- Diana Vucevic (ORCID: https://orcid.org/0000-0001-8291-7610)
- Mitsue Miyazaki (ORCID: https://orcid.org/0000-0002-5690-694X)
- Anya Mesa
Publication Details
- Journal
- Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
- Published
- 2024-11-26
- DOI
- https://doi.org/10.58530/2024/2280
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00