3D Turbo-Spin-Echo with VERSE Excitation Improves SNR for Brachial Plexus Magnetic Resonance Neurography

Motivation: The conventional slab-selective 3D TSE approach for brachial plexus magnetic resonance neurography (MRN) has a longer echo spacing for the first refocusing pulse and hence violates CPMG conditions. The signal available can decrease significantly due to field inhomogeneities. Goal(s): We aimed to improve slab-selective 3D TSE for brachial plexus MRN. Approach: We incorporated the variable-rate selective excitation (VERSE) method to shorten the excitation pulse duration and eliminate the need for the first long-echo-spacing refocusing module. Results: The 3D TSE with VERSE excitation achieved higher SNR in both phantom and in-vivo experiments. Impact: The proposed 3D TSE using VERSE excitation improved slab-selective imaging in brachial plexus MRN with higher SNR when compared to the conventional approach.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0491
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D Turbo-Spin-Echo with VERSE Excitation Improves SNR for Brachial Plexus Magnetic Resonance Neurography

Alto Stemmer, Xiaoying Cai, Ek T. Tan, Peter Kollasch et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

3D Turbo-Spin-Echo with VERSE Excitation Improves SNR for Brachial Plexus Magnetic Resonance Neurography

Alto Stemmer, Xiaoying Cai, Ek T. Tan, Peter Kollasch, Guido Buonincontri, Nicolas Groß‐Weege, Darryl B. Sneag, Michelle Akerman
article en

Abstract

Motivation: The conventional slab-selective 3D TSE approach for brachial plexus magnetic resonance neurography (MRN) has a longer echo spacing for the first refocusing pulse and hence violates CPMG conditions. The signal available can decrease significantly due to field inhomogeneities. Goal(s): We aimed to improve slab-selective 3D TSE for brachial plexus MRN. Approach: We incorporated the variable-rate selective excitation (VERSE) method to shorten the excitation pulse duration and eliminate the need for the first long-echo-spacing refocusing module. Results: The 3D TSE with VERSE excitation achieved higher SNR in both phantom and in-vivo experiments. Impact: The proposed 3D TSE using VERSE excitation improved slab-selective imaging in brachial plexus MRN with higher SNR when compared to the conventional approach.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.