Detection and Correction of Spurious Motion Within Overlapped Multi-Slice Prostate T2-Weighted Acquisitions

Motivation: Motion frequently impairs T2 weighted prostate imaging; in the multi-pass acquisitions that are common this results in an objectionable stair-step artifact, and can lead to additional scans and increased exam time. Goal(s): Reduce the impact of motion occurring in a subset of the multi-pass acquisition. Approach: Automatic detection of motion (through a mutual-information metric) coupled with replacement of corrupted slices via averaging of neighbors. In the described case, adjacent slices are intentionally overlapped, leading to reasonable results from this approach. Results: Improvements are clearly visible in both motion-controlled phantom and a subset of volunteer examinations. Impact: The ability to automatically repair a portion of motion-corrupted exams may enable reduction of supplemental / repeat scans, improving overall exam times. The described technique is not computationally complex, and could be performed inline after scan completion.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4988
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection and Correction of Spurious Motion Within Overlapped Multi-Slice Prostate T2-Weighted Acquisitions

Stephen J. Riederer, Phillip J. Rossman, Eric A. Borisch, Alireza Kazemi et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Cardiac Imaging and Diagnostics
article

Detection and Correction of Spurious Motion Within Overlapped Multi-Slice Prostate T2-Weighted Acquisitions

Stephen J. Riederer, Phillip J. Rossman, Eric A. Borisch, Alireza Kazemi, Roger C. Grimm
article en

Abstract

Motivation: Motion frequently impairs T2 weighted prostate imaging; in the multi-pass acquisitions that are common this results in an objectionable stair-step artifact, and can lead to additional scans and increased exam time. Goal(s): Reduce the impact of motion occurring in a subset of the multi-pass acquisition. Approach: Automatic detection of motion (through a mutual-information metric) coupled with replacement of corrupted slices via averaging of neighbors. In the described case, adjacent slices are intentionally overlapped, leading to reasonable results from this approach. Results: Improvements are clearly visible in both motion-controlled phantom and a subset of volunteer examinations. Impact: The ability to automatically repair a portion of motion-corrupted exams may enable reduction of supplemental / repeat scans, improving overall exam times. The described technique is not computationally complex, and could be performed inline after scan completion.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.