Testing the Quantitative Imaging Biomarkers Alliance (QIBA) PDFF Profile in the Liver: Results from 416 Scanners at 1.5T and 3T

Motivation: The Quantitative Imaging Biomarkers Alliance (QIBA) PDFF Profile describes the expected performance of an imaging technique when measuring PDFF. However, the expected performance in phantoms was determined in one phantom on 27 scanners and may not be applicable widely. Goal(s): We tested the hypothesis that the QIBA PDFF bias criteria (mean:within ±5.0%, maximum:within ±7.0% (percentage points)) cannot be attained at scale with multiple phantoms on >400 scanners. Approach: We calculated the QIBA PDFF criteria using phantom data from 416 scanners across three vendors at 1.5T and 3T. Results: All six combinations of scanner vendor and field strength passed the QIBA PDFF criteria. Impact: The hypothesis that the QIBA PDFF bias criteria cannot be maintained with multiple phantoms on >400 scanners was disproven in a novel dataset with 416 scanners, strongly suggesting that it is possible to achieve this level of performance at scale.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0546
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Testing the Quantitative Imaging Biomarkers Alliance (QIBA) PDFF Profile in the Liver: Results from 416 Scanners at 1.5T and 3T

Matthew J. Robson, R Salvati, Tom Davis, Adrienne Siu et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Radiomics and Machine Learning in Medical Imaging
article

Testing the Quantitative Imaging Biomarkers Alliance (QIBA) PDFF Profile in the Liver: Results from 416 Scanners at 1.5T and 3T

Matthew J. Robson, R Salvati, Tom Davis, Adrienne Siu, Mary Jean Solywoda
article en

Abstract

Motivation: The Quantitative Imaging Biomarkers Alliance (QIBA) PDFF Profile describes the expected performance of an imaging technique when measuring PDFF. However, the expected performance in phantoms was determined in one phantom on 27 scanners and may not be applicable widely. Goal(s): We tested the hypothesis that the QIBA PDFF bias criteria (mean:within ±5.0%, maximum:within ±7.0% (percentage points)) cannot be attained at scale with multiple phantoms on >400 scanners. Approach: We calculated the QIBA PDFF criteria using phantom data from 416 scanners across three vendors at 1.5T and 3T. Results: All six combinations of scanner vendor and field strength passed the QIBA PDFF criteria. Impact: The hypothesis that the QIBA PDFF bias criteria cannot be maintained with multiple phantoms on >400 scanners was disproven in a novel dataset with 416 scanners, strongly suggesting that it is possible to achieve this level of performance at scale.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Testing the Quantitative Imaging Biomarkers Alliance (QIBA) PDFF Profile in the Liver: Results from 416 Scanners at 1.5T and 3T — Matthew J. Robson, R Salvati, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS