Quantitative T2 of Long Post-Labeling-Delay (PLD) ASL Signal as a Reporter of Extravascular Microenvironment

Motivation: Quantitative T2 values of ASL spins may then inform their local microenvironment. Goal(s): In this study, we aim to conduct a technical development to demonstrate the feasibility of measuring ASL T2 at long post-labeling-delay (PLD), at a time when the spins have fully exited the vasculature. Approach: A protocol comprised of Pseudo-Continuous Arterial Spin Labeling (PCASL) module followed by optimized background suppression pulses and 2D multiple-spin-echo (MSE) EPI readout was used to collect T2-weighted images at different post labeling delay (PLD). Results: We estimated T2 of ASL difference signals at long PLDs and also find age related changes in T2 values. Impact: Our result suggests that ASL spins may be used as a reporting probe to assessment the microvascular environment of the brain in health and diseases.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2018
Primary Topic
Electron Spin Resonance Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative T2 of Long Post-Labeling-Delay (PLD) ASL Signal as a Reporter of Extravascular Microenvironment

Dengrong Jiang, Hanzhang Lu, Zhiyi Hu, Sandeep Ganji et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Electron Spin Resonance Studies
article

Quantitative T2 of Long Post-Labeling-Delay (PLD) ASL Signal as a Reporter of Extravascular Microenvironment

Dengrong Jiang, Hanzhang Lu, Zhiyi Hu, Sandeep Ganji, Zihan Wang, Wen Shi, Dinil Sasi Sankaralayam
article en

Abstract

Motivation: Quantitative T2 values of ASL spins may then inform their local microenvironment. Goal(s): In this study, we aim to conduct a technical development to demonstrate the feasibility of measuring ASL T2 at long post-labeling-delay (PLD), at a time when the spins have fully exited the vasculature. Approach: A protocol comprised of Pseudo-Continuous Arterial Spin Labeling (PCASL) module followed by optimized background suppression pulses and 2D multiple-spin-echo (MSE) EPI readout was used to collect T2-weighted images at different post labeling delay (PLD). Results: We estimated T2 of ASL difference signals at long PLDs and also find age related changes in T2 values. Impact: Our result suggests that ASL spins may be used as a reporting probe to assessment the microvascular environment of the brain in health and diseases.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Good health and well-being
Openalex Percentile: Top 86%
Electron Spin Resonance Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.