Four-Channel MM-Wave Radar Testbed for Neck vs Chest Cardiac Sensing

Motivation: Respiratory and cardiac gating are common in modern MRI, but require additional sensors in contact with the patient and the associated cabling. Goal(s): Our goal is to determine if CW mm-wave radar can act as a robust non-contact cardiac and respiratory sensor, with potential for gating in MRI. Approach: A 4-channel 24 GHz radar test bed is developed with a pair of neck radars and a pair of chest radars. SSA and ICA methods help extract waveform structure relative to an ECG. Results: The CW radars nicely separate breathing and heart rate with distinct features at the ECG QRS complex. Impact: MM-wave radar could provide a non-contact sensor of cardiac/breathing in MRI. Potential applications include non-contact gating, and independent vascular pulse or motion sensing for use in neuroimaging.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0677
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Four-Channel MM-Wave Radar Testbed for Neck vs Chest Cardiac Sensing

John M. Pauly, Lauren Hughes, Fraser Robb, Shreyas Vasanawala et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Non-Invasive Vital Sign Monitoring
article

Four-Channel MM-Wave Radar Testbed for Neck vs Chest Cardiac Sensing

John M. Pauly, Lauren Hughes, Fraser Robb, Shreyas Vasanawala, Greig Scott
article en

Abstract

Motivation: Respiratory and cardiac gating are common in modern MRI, but require additional sensors in contact with the patient and the associated cabling. Goal(s): Our goal is to determine if CW mm-wave radar can act as a robust non-contact cardiac and respiratory sensor, with potential for gating in MRI. Approach: A 4-channel 24 GHz radar test bed is developed with a pair of neck radars and a pair of chest radars. SSA and ICA methods help extract waveform structure relative to an ECG. Results: The CW radars nicely separate breathing and heart rate with distinct features at the ECG QRS complex. Impact: MM-wave radar could provide a non-contact sensor of cardiac/breathing in MRI. Potential applications include non-contact gating, and independent vascular pulse or motion sensing for use in neuroimaging.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Good health and well-being
Openalex Percentile: Top 80%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Four-Channel MM-Wave Radar Testbed for Neck vs Chest Cardiac Sensing — John M. Pauly, Lauren Hughes, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS