Deep Learning-Based Automated Kidney and Cortex Segmentation from Non-contrast T1-weighted Images

Motivation: In the realm of kidney imaging, the precise measurement of kidney volumes, including total, cortical, and medullary volumes, is of significant clinical importance, but manual segmentation is time-consuming and impractical. Goal(s): To develop a fully automated deep learning-based segmentation method for segmenting the entire kidney and internal structures in MR images. Approach: Utilized a 3D nnU-Net deep learning model trained with non-contrast-enhanced T1-weight MR images from 40 volunteers, validated against manual segmentation. Results: The automated method strongly correlated with manual measurements (Pearson’s > 0.9) and achieved Dice coefficients of 0.96 for the whole kidney and 0.84 for the cortex on the test set. Impact: This deep learning approach offers rapid, precise, and replicable kidney volume analysis, enhancing both research and clinical care.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2100
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning-Based Automated Kidney and Cortex Segmentation from Non-contrast T1-weighted Images

Caixia Zou, Gang Huang, Luping Shi, Shanshan Jiang et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced X-ray and CT Imaging
article

Deep Learning-Based Automated Kidney and Cortex Segmentation from Non-contrast T1-weighted Images

Caixia Zou, Gang Huang, Luping Shi, Shanshan Jiang, nini pan, Yi Zhu, Lianqiu Xiong
article en

Abstract

Motivation: In the realm of kidney imaging, the precise measurement of kidney volumes, including total, cortical, and medullary volumes, is of significant clinical importance, but manual segmentation is time-consuming and impractical. Goal(s): To develop a fully automated deep learning-based segmentation method for segmenting the entire kidney and internal structures in MR images. Approach: Utilized a 3D nnU-Net deep learning model trained with non-contrast-enhanced T1-weight MR images from 40 volunteers, validated against manual segmentation. Results: The automated method strongly correlated with manual measurements (Pearson’s > 0.9) and achieved Dice coefficients of 0.96 for the whole kidney and 0.84 for the cortex on the test set. Impact: This deep learning approach offers rapid, precise, and replicable kidney volume analysis, enhancing both research and clinical care.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 80%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.