Validation and SAR evaluation of a 16-channel 1H/23Na dipole/loop array for 7T MRI

Motivation: 7T MRI enables 23Na MRI due to enhanced sensitivity. Combined with proton imaging, functional and anatomical information can be acquired to characterise brain status. Goal(s): Establishing safe RF power limits for an in-house built 1H/23Na loop/dipole array for subsequent in-vivo experiments. Approach: Phantom MR results at 7T and electromagnetic simulations were compared to evaluate consistency between experiments and simulations. Human models were simulated to demonstrate SAR10g levels for different patients. Results: Simulated and experimental B1+fields showed high correlation for individual magnitudes and phases. Worst-case SAR10g for human models all remain within safety limits, demonstrating the clinical potential of our proposed coil. Impact: Towards in-vivo RF coil use, we validated simulated RF models of the coil at 23Na/1H frequencies using measured B1+field magnitude and phase maps. Safe RF power limits can therefore be established for research coils to proceed to in-vivo experiments.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3738
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation and SAR evaluation of a 16-channel 1H/23Na dipole/loop array for 7T MRI

Sarah McElroy, Özlem İpek, Joseph V. Hajnal, David W. Carmichael et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Validation and SAR evaluation of a 16-channel 1H/23Na dipole/loop array for 7T MRI

Sarah McElroy, Özlem İpek, Joseph V. Hajnal, David W. Carmichael, Menglu Wu
article en

Abstract

Motivation: 7T MRI enables 23Na MRI due to enhanced sensitivity. Combined with proton imaging, functional and anatomical information can be acquired to characterise brain status. Goal(s): Establishing safe RF power limits for an in-house built 1H/23Na loop/dipole array for subsequent in-vivo experiments. Approach: Phantom MR results at 7T and electromagnetic simulations were compared to evaluate consistency between experiments and simulations. Human models were simulated to demonstrate SAR10g levels for different patients. Results: Simulated and experimental B1+fields showed high correlation for individual magnitudes and phases. Worst-case SAR10g for human models all remain within safety limits, demonstrating the clinical potential of our proposed coil. Impact: Towards in-vivo RF coil use, we validated simulated RF models of the coil at 23Na/1H frequencies using measured B1+field magnitude and phase maps. Safe RF power limits can therefore be established for research coils to proceed to in-vivo experiments.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.