Robust inter-blade and inter-slice motion correction reconstruction for PROPELLER MRI

Motivation: PROPELLER MRI has been widely used to mitigate patient motion; however, conventional approach is not very robust, and does not address inter-slice misalignment that tends to occur on few moving patients. Goal(s): Develop new robust inter-blade and inter-slice motion correction technique. Approach: We propose a novel inter-blade and inter-slice motion correction reconstruction technique for PROPELLER MRI using volumetric calibration scan as reference. Results: The results show large improvement brought by the proposed method compared to convention Motion Correction on both in-plane motion artifact mitigation and inter-slice alignment. Impact: Reducing repeat scans due to patient motion, hence, increase patient throughput. Enable scanning patient who cannot keep still in the scanner, such as pediatric patients.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4647
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust inter-blade and inter-slice motion correction reconstruction for PROPELLER MRI

Ajeet Gaddipati, Ali Ersöz, Shaorong Chang, Xucheng Zhu et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Robust inter-blade and inter-slice motion correction reconstruction for PROPELLER MRI

Ajeet Gaddipati, Ali Ersöz, Shaorong Chang, Xucheng Zhu, Min Wei, Piero Ghedin
article en

Abstract

Motivation: PROPELLER MRI has been widely used to mitigate patient motion; however, conventional approach is not very robust, and does not address inter-slice misalignment that tends to occur on few moving patients. Goal(s): Develop new robust inter-blade and inter-slice motion correction technique. Approach: We propose a novel inter-blade and inter-slice motion correction reconstruction technique for PROPELLER MRI using volumetric calibration scan as reference. Results: The results show large improvement brought by the proposed method compared to convention Motion Correction on both in-plane motion artifact mitigation and inter-slice alignment. Impact: Reducing repeat scans due to patient motion, hence, increase patient throughput. Enable scanning patient who cannot keep still in the scanner, such as pediatric patients.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.