Free-breathing 3D Radial DIXON Look-Locker sequence for whole-liver simultaneous quantification of water/fat separated T1 and PDFF

Motivation: T1 and PDFF mapping, which could serve as imaging biomarkers for liver disease, require breath-holds; T1 mapping commonly used in clinical practice, such as MOLLI, has limited spatial coverage. In addition, the presence of liver fat reduces T1 accuracy. Goal(s): Our goal is to enable simultaneous whole liver water/fat separated T1 and PDFF quantification with clinically acceptable accuracy without breath-holds. Approach: We introduced the 3D Radial DIXON LL sequence and validated in phantom and in vivo. Results: Free-breathing 3D Radial Dixon LL sequence results in a proportional bias for T1 measurement and the fixed bias for PDFF measurement compared to current standard techniques. Impact: The 3D Radial Dixon LL sequence did not result in sufficiently good agreement with reference methods for water/fat separated T1 and PDFF, suggesting that further technical validation and the optimization of imaging parameters will be needed.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4632
Citations
1
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Free-breathing 3D Radial DIXON Look-Locker sequence for whole-liver simultaneous quantification of water/fat separated T1 and PDFF

Shigeru Shibata, Marc Van Cauteren, Makoto Obara, Kazunori Moriya et al.
1 citations
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Body Composition Measurement Techniques
0.33
article

Free-breathing 3D Radial DIXON Look-Locker sequence for whole-liver simultaneous quantification of water/fat separated T1 and PDFF

Shigeru Shibata, Marc Van Cauteren, Makoto Obara, Kazunori Moriya, Masami Yoneyama, Tsutomu Tamada, Yoshihiko Fukukura, Jihun Kwon, Yu Ueda, Kota Amo
article en
1 citations

Abstract

Motivation: T1 and PDFF mapping, which could serve as imaging biomarkers for liver disease, require breath-holds; T1 mapping commonly used in clinical practice, such as MOLLI, has limited spatial coverage. In addition, the presence of liver fat reduces T1 accuracy. Goal(s): Our goal is to enable simultaneous whole liver water/fat separated T1 and PDFF quantification with clinically acceptable accuracy without breath-holds. Approach: We introduced the 3D Radial DIXON LL sequence and validated in phantom and in vivo. Results: Free-breathing 3D Radial Dixon LL sequence results in a proportional bias for T1 measurement and the fixed bias for PDFF measurement compared to current standard techniques. Impact: The 3D Radial Dixon LL sequence did not result in sufficiently good agreement with reference methods for water/fat separated T1 and PDFF, suggesting that further technical validation and the optimization of imaging parameters will be needed.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 36%
Body Composition Measurement Techniques
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Free-breathing 3D Radial DIXON Look-Locker sequence for whole-liver simultaneous quantification of water/fat separated T1 and PDFF — Shigeru Shibata, Marc Van Cauteren, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS