Simulation-based optimization and experimental comparison of intracranial T2-weighted DANTE-SPACE vessel wall imaging at 3T and 7T

Motivation: T2-weighted DANTE-SPACE is a promising sequence for intracranial black-blood vessel wall imaging at 7T. However, it is limited by signal and contrast variations and its performance versus 3T remains unclear. Goal(s): To optimize T2-weighted DANTE-SPACE at both 3T and 7T, and to quantitatively compare their performance. Approach: A recently introduced DANTE-SPACE simulation framework was used for protocol optimization. Data acquired from six healthy volunteers at 3T and 7T were then quantitatively compared. Results: Optimization of DANTE-SPACE parameters at 7T provides a 24% increase in vessel visibility over a literature protocol. Contrasts at 7T are 90% higher than at 3T. Impact: Through simulation-based optimization, the vessel wall contrasts from T2-weighted DANTE-SPACE at 7T were improved by 24% versus a literature protocol. When optimized and implemented at 3T, in-vivo data showed a much lower vessel wall contrast-to-noise relative to 7T.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/1343
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation-based optimization and experimental comparison of intracranial T2-weighted DANTE-SPACE vessel wall imaging at 3T and 7T

Aaron T. Hess, Matthijs de Buck, Peter Jezzard
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Cerebrovascular and Carotid Artery Diseases
article

Simulation-based optimization and experimental comparison of intracranial T2-weighted DANTE-SPACE vessel wall imaging at 3T and 7T

Aaron T. Hess, Matthijs de Buck, Peter Jezzard
article en

Abstract

Motivation: T2-weighted DANTE-SPACE is a promising sequence for intracranial black-blood vessel wall imaging at 7T. However, it is limited by signal and contrast variations and its performance versus 3T remains unclear. Goal(s): To optimize T2-weighted DANTE-SPACE at both 3T and 7T, and to quantitatively compare their performance. Approach: A recently introduced DANTE-SPACE simulation framework was used for protocol optimization. Data acquired from six healthy volunteers at 3T and 7T were then quantitatively compared. Results: Optimization of DANTE-SPACE parameters at 7T provides a 24% increase in vessel visibility over a literature protocol. Contrasts at 7T are 90% higher than at 3T. Impact: Through simulation-based optimization, the vessel wall contrasts from T2-weighted DANTE-SPACE at 7T were improved by 24% versus a literature protocol. When optimized and implemented at 3T, in-vivo data showed a much lower vessel wall contrast-to-noise relative to 7T.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 60%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.