CSF Mimicking Phantom based Evaluation of CSF Flow using Phase Contrast and Diffusion Imaging on a Highly Efficient Head Only Gradient System

Motivation: Accurate characterization of CSF flow dynamics is necessary for understanding of brain metabolite clearance pathways. Goal(s): To compare PC and DWI techniques for slow CSF flow velocity at 3T in a clinical scanner and a heald-only high performance gradient system using high fidelity ventricle phantoms. Approach: Flow pump experiments were performed on silicone phantom at each of the scanners using varying Vencs. Results: Greater velocity-to-noise ratio (VNR) gains and diffusion sensitivity were observed from scans collected on the high performance gradient systemImpact: Generating physiologically realistic cerebral ventricles phantom and leveraging high performance gradient systems can enable low CSF flow assessment for studying brain waste clearance pathways.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4040
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CSF Mimicking Phantom based Evaluation of CSF Flow using Phase Contrast and Diffusion Imaging on a Highly Efficient Head Only Gradient System

Kevin M. Johnson, James A. Rice, Leonardo A. Rivera‐Rivera, Alejandro Roldán‐Alzate et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Atomic and Subatomic Physics Research
article

CSF Mimicking Phantom based Evaluation of CSF Flow using Phase Contrast and Diffusion Imaging on a Highly Efficient Head Only Gradient System

Kevin M. Johnson, James A. Rice, Leonardo A. Rivera‐Rivera, Alejandro Roldán‐Alzate, Brock Jolicoeur
article en

Abstract

Motivation: Accurate characterization of CSF flow dynamics is necessary for understanding of brain metabolite clearance pathways. Goal(s): To compare PC and DWI techniques for slow CSF flow velocity at 3T in a clinical scanner and a heald-only high performance gradient system using high fidelity ventricle phantoms. Approach: Flow pump experiments were performed on silicone phantom at each of the scanners using varying Vencs. Results: Greater velocity-to-noise ratio (VNR) gains and diffusion sensitivity were observed from scans collected on the high performance gradient systemImpact: Generating physiologically realistic cerebral ventricles phantom and leveraging high performance gradient systems can enable low CSF flow assessment for studying brain waste clearance pathways.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 81%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.