Ultra-Short Echo-Time Based Accelerated Four-Dimensional Rosette J-resolved Spectroscopic Imaging (4D UTE-ROS-JRESI): A pilot study
Motivation: Two-dimensional spectrum resolves information-coupled metabolites along an additional spectral dimension. However, acquisition after adding the 2nd spectral encoding can increase the total acquisition time significantly. Goal(s): To achieve clinically feasible runtimes for J-resolved Spectroscopic Imaging (JRESI) using Ultra-Short Echo-Time (UTE) based sequence implementation. Approach: Implement a UTE based 4D JRESI sequence with rosette readout, which would enable shorter repetition times and use of higher undersampling factors. Results: This study demonstrated in-vivo 4D UTE-ROSE-JRESI in less than 10 minutes as compared to a semi-laser sequence with a TR of 1.5 seconds which will take 17 minutes for the same sequence. Impact: With higher incoherence level of sampling patterns rosette based spectroscopic imaging sequence showed the potential for highly accelerated acquisitions. Using UTE based rosette 4D J-resolved Spectroscopic Imaging sequence allowed further reduction in scan time with the help of shorter TR.
Authors
- Uzay E. Emir (ORCID: https://orcid.org/0000-0001-5376-0431)
- Paul M. Macey (ORCID: https://orcid.org/0000-0003-4093-7458)
- M. Albert Thomas (ORCID: https://orcid.org/0000-0001-9037-2585)
- Ajin Joy
Publication Details
- Journal
- Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
- Published
- 2024-11-26
- DOI
- https://doi.org/10.58530/2024/1146
- Primary Topic
- NMR spectroscopy and applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00