Optimization of 3D PCASL perfusion SNR efficiency at 7T

Motivation: 3D-PCASL is a well-established perfusion MRI technique at 3T. Nonetheless, its effectiveness is hampered by increased RF power deposition at 7T limiting the SNR efficiency and labeling duration. Goal(s): This work investigates the relationship between gray matter perfusion signal and labeling duration aiming to optimize 3D-PCASL SNR efficiency while taking into consideration the increased RF power constraints of 7T MRI. Approach: SNR efficiency was measured at various labeling durations maintaining scan time to ~6 min and SAR to ~90% of first-level mode limit at 7T. Results: Optimal SNR efficiency was obtained at labeling duration of ~3 s. Impact: The result of this work provides optimal labeling duration for 7T 3D PCASL studies with maximum SNR per unit time taking into account first-level mode RF power limits.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2003
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of 3D PCASL perfusion SNR efficiency at 7T

Alan P. Koretsky, Gaël Saïb, S. Lalith Talagala, Sunil Patil
2 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Optimization of 3D PCASL perfusion SNR efficiency at 7T

Alan P. Koretsky, Gaël Saïb, S. Lalith Talagala, Sunil Patil
article en

Abstract

Motivation: 3D-PCASL is a well-established perfusion MRI technique at 3T. Nonetheless, its effectiveness is hampered by increased RF power deposition at 7T limiting the SNR efficiency and labeling duration. Goal(s): This work investigates the relationship between gray matter perfusion signal and labeling duration aiming to optimize 3D-PCASL SNR efficiency while taking into consideration the increased RF power constraints of 7T MRI. Approach: SNR efficiency was measured at various labeling durations maintaining scan time to ~6 min and SAR to ~90% of first-level mode limit at 7T. Results: Optimal SNR efficiency was obtained at labeling duration of ~3 s. Impact: The result of this work provides optimal labeling duration for 7T 3D PCASL studies with maximum SNR per unit time taking into account first-level mode RF power limits.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Affordable and clean energy
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.