Measurement of pancreas graft temperature during cold preservation in MR scanner

Motivation: Phosphorus (31P) and proton (1H) MRS are methods of choice in assessment of pancreas graft quality before transplantation. Since MR scanning can increase the temperature of the pancreas graft, measurement of the graft temperature is desirable. Goal(s): The aim of this study was to investigate if it is possible to measure pancreas graft temperature in MR scanner using 1H-MRS. Approach: Single-voxel 1H-MRS. Temperature constants were obtained by calibration experiments with the water-vegetable oil phantom. Results: The present study has shown that 1H-MRS is able to measure the graft temperature during MR scanning. Impact: 1H-MRS is able to measure the pancreas graft temperature during MR scanning. The temperature is computed from the chemical shift difference between water spectral line and methylene (CH2)n line originating from the pancreatic adipocytes.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4008
Primary Topic
Machine Learning and ELM
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of pancreas graft temperature during cold preservation in MR scanner

Ján Weis, Olle Korsgren
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Machine Learning and ELM
article

Measurement of pancreas graft temperature during cold preservation in MR scanner

Ján Weis, Olle Korsgren
article en

Abstract

Motivation: Phosphorus (31P) and proton (1H) MRS are methods of choice in assessment of pancreas graft quality before transplantation. Since MR scanning can increase the temperature of the pancreas graft, measurement of the graft temperature is desirable. Goal(s): The aim of this study was to investigate if it is possible to measure pancreas graft temperature in MR scanner using 1H-MRS. Approach: Single-voxel 1H-MRS. Temperature constants were obtained by calibration experiments with the water-vegetable oil phantom. Results: The present study has shown that 1H-MRS is able to measure the graft temperature during MR scanning. Impact: 1H-MRS is able to measure the pancreas graft temperature during MR scanning. The temperature is computed from the chemical shift difference between water spectral line and methylene (CH2)n line originating from the pancreatic adipocytes.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 81%
Machine Learning and ELM
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.