Image navigators insensitive to B0 inhomogeneity for optimal prospective motion-corrected MRS

Motivation: Navigator-based prospective motion-corrected MRS is often performed with 2nd order shims optimized in the whole brain to prevent degradation of navigator images, resulting in suboptimal linewidth. Goal(s): Here, we report image-based prospective motion correction with 2nd order shims adjusted in the MRS voxel while maintaining good navigator image quality despite the strong B0 inhomogeneity outside the voxel. Approach: This was achieved by segmenting multislice spiral navigator images to reduce blurring artifacts from inhomogeneous B0 fields. Results: High-quality spectra with optimal linewidth were acquired in the presence of subject motion at 3T and 7T, demonstrating the feasibility of this new approach on clinical scanners. Impact: Image-based prospective motion correction with optimal localized B0 shim (1st and 2nd order) in the MRS voxel is feasible in the human brain at 3T and 7T.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/1855
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Image navigators insensitive to B0 inhomogeneity for optimal prospective motion-corrected MRS

Isaac Adanyeguh, Dinesh K. Deelchand, Pierre-Gilles Henry
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Medical Image Segmentation Techniques
article

Image navigators insensitive to B0 inhomogeneity for optimal prospective motion-corrected MRS

Isaac Adanyeguh, Dinesh K. Deelchand, Pierre-Gilles Henry
article en

Abstract

Motivation: Navigator-based prospective motion-corrected MRS is often performed with 2nd order shims optimized in the whole brain to prevent degradation of navigator images, resulting in suboptimal linewidth. Goal(s): Here, we report image-based prospective motion correction with 2nd order shims adjusted in the MRS voxel while maintaining good navigator image quality despite the strong B0 inhomogeneity outside the voxel. Approach: This was achieved by segmenting multislice spiral navigator images to reduce blurring artifacts from inhomogeneous B0 fields. Results: High-quality spectra with optimal linewidth were acquired in the presence of subject motion at 3T and 7T, demonstrating the feasibility of this new approach on clinical scanners. Impact: Image-based prospective motion correction with optimal localized B0 shim (1st and 2nd order) in the MRS voxel is feasible in the human brain at 3T and 7T.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 79%
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.