Reduction of RF-heating on bilateral DBS leads using two channel RF-shimming on 3T MRI

Motivation: Bilateral deep brain stimulation (DBS) surgery would benefit from safe intraoperative 3T MRI using conventional scanners. Goal(s): Our goal was to develop a method to determine patient-specific safety constraints to scan a bilateral lead configuration with minimal RF-heating, by minimizing RF-induced currents at maximal B1. Approach: We scanned a phantom with two leads in different configurations, measured local heating and determined the transimpedance. Results: We could determine the phantom-specific safety constraints and find a low-SAR sequence meeting the constraints, after optimizing the two channel RF-shimming to minimize RF-heating by minimizing RF-induced currents at maximal B1. Impact: The proposed method can be used to minimize heating of a bilateral lead configuration and estimate patient-specific safety constraints, but further research has to be conducted to be able to use it during deep brain stimulation surgery.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3726
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reduction of RF-heating on bilateral DBS leads using two channel RF-shimming on 3T MRI

Wyger M. Brink, Ruud Vinke, Marinette van der Graaf, C.D.E. Van Speybroeck et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Reduction of RF-heating on bilateral DBS leads using two channel RF-shimming on 3T MRI

Wyger M. Brink, Ruud Vinke, Marinette van der Graaf, C.D.E. Van Speybroeck, W. Roskamp
article en

Abstract

Motivation: Bilateral deep brain stimulation (DBS) surgery would benefit from safe intraoperative 3T MRI using conventional scanners. Goal(s): Our goal was to develop a method to determine patient-specific safety constraints to scan a bilateral lead configuration with minimal RF-heating, by minimizing RF-induced currents at maximal B1. Approach: We scanned a phantom with two leads in different configurations, measured local heating and determined the transimpedance. Results: We could determine the phantom-specific safety constraints and find a low-SAR sequence meeting the constraints, after optimizing the two channel RF-shimming to minimize RF-heating by minimizing RF-induced currents at maximal B1. Impact: The proposed method can be used to minimize heating of a bilateral lead configuration and estimate patient-specific safety constraints, but further research has to be conducted to be able to use it during deep brain stimulation surgery.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.