Rapid T2 mapping with blip-reversed multi-echo planar imaging

Motivation: Current methods for T2 mapping are time-consuming and susceptible to motion artifacts, hindering their clinical utility. Goal(s): Our goal is to develop a rapid and motion-robust T2 mapping technique. By significantly reducing scan times and eliminating motion artifacts, we aim to enhance the clinical feasibility of quantitative T2 mapping across diverse patient populations. Approach: Standard spin-echo EPI sequence was modified by incorporating additional readouts with alternating phase-encoding directions. Geometric distortions due to susceptibility-induced effects were corrected using TOPUP tool. Results: T2 maps generated using our sequence showed good correspondence with the T2 map from 3D GRASE reference both in phantom and volunteer studies. Impact: Our single-shot T2 mapping technique based on multi-echo spin echo EPI sequence not only advances imaging speed and accuracy but also caters to uncooperative populations, including pediatric patients and individuals prone to movement.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3824
Primary Topic
Geological and Geophysical Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid T2 mapping with blip-reversed multi-echo planar imaging

Mustafa Ütkür, Liam Timms, Onur Afacan, Tess Wallace et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Geological and Geophysical Studies
article

Rapid T2 mapping with blip-reversed multi-echo planar imaging

Mustafa Ütkür, Liam Timms, Onur Afacan, Tess Wallace, Sila Kurugol, Zhe Wang
article en

Abstract

Motivation: Current methods for T2 mapping are time-consuming and susceptible to motion artifacts, hindering their clinical utility. Goal(s): Our goal is to develop a rapid and motion-robust T2 mapping technique. By significantly reducing scan times and eliminating motion artifacts, we aim to enhance the clinical feasibility of quantitative T2 mapping across diverse patient populations. Approach: Standard spin-echo EPI sequence was modified by incorporating additional readouts with alternating phase-encoding directions. Geometric distortions due to susceptibility-induced effects were corrected using TOPUP tool. Results: T2 maps generated using our sequence showed good correspondence with the T2 map from 3D GRASE reference both in phantom and volunteer studies. Impact: Our single-shot T2 mapping technique based on multi-echo spin echo EPI sequence not only advances imaging speed and accuracy but also caters to uncooperative populations, including pediatric patients and individuals prone to movement.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 55%
Geological and Geophysical Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.