Lorentzian fitting of Average Rotation of Saturation Effects (AROSE) CEST spectra for quantification in stroke

Motivation: Fitting of CEST spectra is obscured by MT, direct water saturation, and broad fast exchange peaks which result in contamination of quantified signals. Goal(s): Using AROSE spectra for fitting simplifies CEST quantification by reducing the need for isolation of CEST signals due to preemptive filtering. Approach: Fitting was first performed on simulated spectra at different exchange rates and then applied to in vivo data. Results: Our results in MCAO rodents showed that quantification of CEST signal from AROSERRex spectra resulted in low fitting residuals with robust peaks at 3.6, 2.6, and 2 ppm and minimal contamination from MT and fast exchanges. Impact: Fitting using AROSE-CEST spectra improves quantification of CEST exchange by minimizing contributions from broad fast exchanges and other contaminations such as MT which have been challenges for traditional fitting methods such as multiple -pool Lorentzian fitting.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4446
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lorentzian fitting of Average Rotation of Saturation Effects (AROSE) CEST spectra for quantification in stroke

Julius Juhyun Chung, Tao Jin
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Lorentzian fitting of Average Rotation of Saturation Effects (AROSE) CEST spectra for quantification in stroke

Julius Juhyun Chung, Tao Jin
article en

Abstract

Motivation: Fitting of CEST spectra is obscured by MT, direct water saturation, and broad fast exchange peaks which result in contamination of quantified signals. Goal(s): Using AROSE spectra for fitting simplifies CEST quantification by reducing the need for isolation of CEST signals due to preemptive filtering. Approach: Fitting was first performed on simulated spectra at different exchange rates and then applied to in vivo data. Results: Our results in MCAO rodents showed that quantification of CEST signal from AROSERRex spectra resulted in low fitting residuals with robust peaks at 3.6, 2.6, and 2 ppm and minimal contamination from MT and fast exchanges. Impact: Fitting using AROSE-CEST spectra improves quantification of CEST exchange by minimizing contributions from broad fast exchanges and other contaminations such as MT which have been challenges for traditional fitting methods such as multiple -pool Lorentzian fitting.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.