Comparison of Fat Navigators and Optical Camera Based Retrospective Motion Correction

Motivation: A comparison between efficacies of navigators and optical camera in retrospective motion correction (MC) on brain MR images remains largely unknown. Goal(s): Our goal was to compare two motion tracking techniques (fat navigators [FatNav] and markerless optical camera [MoCAP]) and their performance in MC. Approach: Twenty-one healthy subjects were imaged by T2-weighted turbo-spin-echo sequence with their head movements monitored simultaneously by both techniques. Performance was evaluated by image sharpness calculated at lateral ventricle/white matter boundary. Results: Compared to MoCAP, FatNav had lower motion scores and less fluctuations at small motion. Images after FatNav-based MC showed greater sharpness than MoCAP. Impact: The better performance of FatNav-based MC despite low temporal resolution suggest that FatNav can be integrated with MoCAP to achieve robust image quality in the presence of both abrupt and slow head motions.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2668
Primary Topic
Digital Media and Visual Art
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Fat Navigators and Optical Camera Based Retrospective Motion Correction

Xiaolin Diao, Xiaopeng Zong, Yichen Zhou, Han Zhang et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Digital Media and Visual Art
article

Comparison of Fat Navigators and Optical Camera Based Retrospective Motion Correction

Xiaolin Diao, Xiaopeng Zong, Yichen Zhou, Han Zhang, Bing Zhao, Lixuan Zhu
article en

Abstract

Motivation: A comparison between efficacies of navigators and optical camera in retrospective motion correction (MC) on brain MR images remains largely unknown. Goal(s): Our goal was to compare two motion tracking techniques (fat navigators [FatNav] and markerless optical camera [MoCAP]) and their performance in MC. Approach: Twenty-one healthy subjects were imaged by T2-weighted turbo-spin-echo sequence with their head movements monitored simultaneously by both techniques. Performance was evaluated by image sharpness calculated at lateral ventricle/white matter boundary. Results: Compared to MoCAP, FatNav had lower motion scores and less fluctuations at small motion. Images after FatNav-based MC showed greater sharpness than MoCAP. Impact: The better performance of FatNav-based MC despite low temporal resolution suggest that FatNav can be integrated with MoCAP to achieve robust image quality in the presence of both abrupt and slow head motions.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 57%
Digital Media and Visual Art
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.