Comparison at 7T of the Impulse head gradient and whole-body SC72 gradient transfer functions.

Motivation: Ultra-high field MRI requires high performance and accurate gradients to push forward the spatio-temporal resolution, especially for fMRI scans. Goal(s): Compare two commercial gradient coils (whole-body SC72 and head-only Impulse) available on 7T scanners. Approach: Characterization of the gradient transfer function (GTF) and measurement of field perturbations following a spoiler gradient using a field camera. Results: The Impulse gradient coil revealed a smooth GTF profile while the SC72 gradient coil exhibited strong resonances. Field oscillations following a spoiler gradient were greatly reduced with the Impulse gradient. Disconnecting the 3rd order shim coils on the SC72 gradient coil improved the quality of its response. Impact: The GTF of the head-only Impulse gradient coil yields interesting prospects. It remains to be determined whether the apparent benefits versus the SC72 are due to the absence of third order shim coils.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4073
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison at 7T of the Impulse head gradient and whole-body SC72 gradient transfer functions.

David R. Feinberg, Sajjad Feizollah, Caroline Le Ster, Franck Mauconduit et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Comparison at 7T of the Impulse head gradient and whole-body SC72 gradient transfer functions.

David R. Feinberg, Sajjad Feizollah, Caroline Le Ster, Franck Mauconduit, Alexander J. S. Beckett, Christine Tardif, An T. Vu, Nicolas Boulant
article en

Abstract

Motivation: Ultra-high field MRI requires high performance and accurate gradients to push forward the spatio-temporal resolution, especially for fMRI scans. Goal(s): Compare two commercial gradient coils (whole-body SC72 and head-only Impulse) available on 7T scanners. Approach: Characterization of the gradient transfer function (GTF) and measurement of field perturbations following a spoiler gradient using a field camera. Results: The Impulse gradient coil revealed a smooth GTF profile while the SC72 gradient coil exhibited strong resonances. Field oscillations following a spoiler gradient were greatly reduced with the Impulse gradient. Disconnecting the 3rd order shim coils on the SC72 gradient coil improved the quality of its response. Impact: The GTF of the head-only Impulse gradient coil yields interesting prospects. It remains to be determined whether the apparent benefits versus the SC72 are due to the absence of third order shim coils.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Affordable and clean energy
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines