Dynamic B0 field shimming for improving pseudo-continuous arterial spin labeling at 7 Tesla

Motivation: Increased B0 inhomogeneity along the length of brain-feeding arteries at 7 Tesla is one major issue for pseudo-continuous arterial spin labeling (PCASL), which reduces the labeling efficiency, leading to loss of perfusion signal. Goal(s): Our goal is to improve PCASL at 7 Tesla by specifically improving B0 field homogeneity of the vessels within the inversion region. Approach: We propose a vessel-specific dynamic B0 shimming method to optimize labeling efficiency without compromising the static shim over the imaging region. Results: Preliminary perfusion images indicate the superior performance of our proposed 3D dynamic shimming method over global or 2D-based correction methods. Impact: Our proposed dynamic B0 shimming method demonstrates strong potential in improving the robustness and effectiveness of PCASL, allowing the high sensitivity and spatial resolution of 7T ASL to be fully utilized.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2019
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic B0 field shimming for improving pseudo-continuous arterial spin labeling at 7 Tesla

Joseph G. Woods, Yang Ji, LI Hong-we, Thomas W. Okell
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Dynamic B0 field shimming for improving pseudo-continuous arterial spin labeling at 7 Tesla

Joseph G. Woods, Yang Ji, LI Hong-we, Thomas W. Okell
article en

Abstract

Motivation: Increased B0 inhomogeneity along the length of brain-feeding arteries at 7 Tesla is one major issue for pseudo-continuous arterial spin labeling (PCASL), which reduces the labeling efficiency, leading to loss of perfusion signal. Goal(s): Our goal is to improve PCASL at 7 Tesla by specifically improving B0 field homogeneity of the vessels within the inversion region. Approach: We propose a vessel-specific dynamic B0 shimming method to optimize labeling efficiency without compromising the static shim over the imaging region. Results: Preliminary perfusion images indicate the superior performance of our proposed 3D dynamic shimming method over global or 2D-based correction methods. Impact: Our proposed dynamic B0 shimming method demonstrates strong potential in improving the robustness and effectiveness of PCASL, allowing the high sensitivity and spatial resolution of 7T ASL to be fully utilized.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.