Preliminary study of a receive Multi-Loop Coil (MLC) array for 7T brain MRI

Motivation: The use of MLCs has shown the potential to improve the SNR at short distance as compared to an equivalent SLC. Goal(s): Evaluation of the performances of a 8-channels MLC-array for head imaging at 7T. Approach: Electromagnetic simulation was used to evaluate and compare the SNR, noise-covariance matrix and g-maps obtained with the MLC-array and with an equivalent array of SLC. Results: As compared to the SLC-array, the MLC-array achieves an increased SNR in a relatively large peripheral ring and a reduced maximum g-factor. Impact: Array of MLC represents a valuable strategy for array developpement at high field that can be employed to improve the SNR or reduce the number of channels.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/1445
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary study of a receive Multi-Loop Coil (MLC) array for 7T brain MRI

Alexis Amadon, Marie Poirier‐Quinot, Paul‐François Gapais, Jean‐Christophe Ginéfri et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Preliminary study of a receive Multi-Loop Coil (MLC) array for 7T brain MRI

Alexis Amadon, Marie Poirier‐Quinot, Paul‐François Gapais, Jean‐Christophe Ginéfri, Alexandre Vignaud, Clément Thibault, C. Dubuc
article en

Abstract

Motivation: The use of MLCs has shown the potential to improve the SNR at short distance as compared to an equivalent SLC. Goal(s): Evaluation of the performances of a 8-channels MLC-array for head imaging at 7T. Approach: Electromagnetic simulation was used to evaluate and compare the SNR, noise-covariance matrix and g-maps obtained with the MLC-array and with an equivalent array of SLC. Results: As compared to the SLC-array, the MLC-array achieves an increased SNR in a relatively large peripheral ring and a reduced maximum g-factor. Impact: Array of MLC represents a valuable strategy for array developpement at high field that can be employed to improve the SNR or reduce the number of channels.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.