Repeatability of Standalone versus Image-Acquisition-Integrated 129Xe Spectroscopy

Motivation: 129Xe spectral parameters of lung airspaces, membrane tissues and red blood cells (RBC), provided by an MRS calibration scan, are important indicators of gas exchange function. Goal(s): Currently, such spectra are often acquired separately from gas exchange images, but it may be feasible to integrate 129Xe gas-exchange MRI and MRS into one scan, and test its repeatability. Approach: In this study, we assess the performance of image-acquisition-integrated spectra and compare them with a dedicated spectroscopicacquisition. Results: In subjects with a range of diseases, image-acquisition-integrated spectra were less repeatable than dedicated ones. However, increasing the number of averaged FIDS to 1second may yield equivalent performance. Impact: The repeatability of 129Xe spectroscopy integrated with imaging would be improved by collecting and averaging at least 1 second of data.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4761
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Repeatability of Standalone versus Image-Acquisition-Integrated 129Xe Spectroscopy

David Mummy, Aryil Bechtel, John P. Mugler, Yi Zheng et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Medical Imaging Techniques and Applications
article

Repeatability of Standalone versus Image-Acquisition-Integrated 129Xe Spectroscopy

David Mummy, Aryil Bechtel, John P. Mugler, Yi Zheng, Bastiaan Driehuys, Anna Costelle, Shuo Zhang
article en

Abstract

Motivation: 129Xe spectral parameters of lung airspaces, membrane tissues and red blood cells (RBC), provided by an MRS calibration scan, are important indicators of gas exchange function. Goal(s): Currently, such spectra are often acquired separately from gas exchange images, but it may be feasible to integrate 129Xe gas-exchange MRI and MRS into one scan, and test its repeatability. Approach: In this study, we assess the performance of image-acquisition-integrated spectra and compare them with a dedicated spectroscopicacquisition. Results: In subjects with a range of diseases, image-acquisition-integrated spectra were less repeatable than dedicated ones. However, increasing the number of averaged FIDS to 1second may yield equivalent performance. Impact: The repeatability of 129Xe spectroscopy integrated with imaging would be improved by collecting and averaging at least 1 second of data.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Good health and well-being
Openalex Percentile: Top 64%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.