Reducing motion artefact in high resolution 7T scans using a new head stabilisation device

Motivation: Long scan durations and ultra-high field both facilitate the acquisition of high-resolution quantitative brain MRI, but they increase motion sensitivity. Goal(s): We aimed to limit the occurrence of deliberate motion by testing a device (‘MinMo’) designed to increase head stability at 7T. Approach: Using two k-space phase encoding orders with different motion sensitivity profiles we obtained data with and without the MinMo device. Results: This showed that the MinMo increased image quality visually and as measured quantitatively via reduced gradient entropy in scans of ~10 and ~20 minute duration. Impact: Reducing head motion would have a significant impact on image quality in high-resolution long duration research scans and clinical imaging. A preliminary investigation of a prototype device aiming to stabilize the head showed efficacy in most subjects, warranting further investigation.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/1406
Primary Topic
Optical Systems and Laser Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing motion artefact in high resolution 7T scans using a new head stabilisation device

Frederic Dick, Yannick Brackenier, Martina F. Callaghan, Simon Richardson et al.
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Optical Systems and Laser Technology
article

Reducing motion artefact in high resolution 7T scans using a new head stabilisation device

Frederic Dick, Yannick Brackenier, Martina F. Callaghan, Simon Richardson, David W. Carmichael, Jyoti Mangal, Pierluigi Di Ciò
article en

Abstract

Motivation: Long scan durations and ultra-high field both facilitate the acquisition of high-resolution quantitative brain MRI, but they increase motion sensitivity. Goal(s): We aimed to limit the occurrence of deliberate motion by testing a device (‘MinMo’) designed to increase head stability at 7T. Approach: Using two k-space phase encoding orders with different motion sensitivity profiles we obtained data with and without the MinMo device. Results: This showed that the MinMo increased image quality visually and as measured quantitatively via reduced gradient entropy in scans of ~10 and ~20 minute duration. Impact: Reducing head motion would have a significant impact on image quality in high-resolution long duration research scans and clinical imaging. A preliminary investigation of a prototype device aiming to stabilize the head showed efficacy in most subjects, warranting further investigation.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 81%
Optical Systems and Laser Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.