Advancing pediatric quantitative MSK through tailored denoising of routine acquisitions developed on an piglet model of LCPD

Motivation: Denoising algorithms may significantly improve the SNR of relaxation time maps of the bone and cartilage. Goal(s): To compare the performance of T-NORDIC and MPPCA denoising techniques for 3D T2 mapping of the femoral head. Approach: 3D T2 maps of the femoral heads from 12 piglets imaged at 3T MRI were denoised using MPPCA and T-NORDIC with parametric dimensions of 4 and 12. The results of qualitatively and quantitatively compared for image quality and quantitative accuracy. Results: T-NORDIC provided superior performance with limited parametric dimension (4 weighted images), demonstrating its promise for magnetization-prepared mapping sequences of the hip joint. Impact: T2 relaxation time mapping is critically investigated for addressing several MSK related diagnosis, but possibly due to thin and sensitive structures in the femoral head even slightest of the perturbations can lead to ineffective computation of quantitative mapping.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/1525
Primary Topic
Phonocardiography and Auscultation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing pediatric quantitative MSK through tailored denoising of routine acquisitions developed on an piglet model of LCPD

Erick Buko, Steen Moeller, Casey P. Johnson, Suhail Parvaze
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Phonocardiography and Auscultation Techniques
article

Advancing pediatric quantitative MSK through tailored denoising of routine acquisitions developed on an piglet model of LCPD

Erick Buko, Steen Moeller, Casey P. Johnson, Suhail Parvaze
article en

Abstract

Motivation: Denoising algorithms may significantly improve the SNR of relaxation time maps of the bone and cartilage. Goal(s): To compare the performance of T-NORDIC and MPPCA denoising techniques for 3D T2 mapping of the femoral head. Approach: 3D T2 maps of the femoral heads from 12 piglets imaged at 3T MRI were denoised using MPPCA and T-NORDIC with parametric dimensions of 4 and 12. The results of qualitatively and quantitatively compared for image quality and quantitative accuracy. Results: T-NORDIC provided superior performance with limited parametric dimension (4 weighted images), demonstrating its promise for magnetization-prepared mapping sequences of the hip joint. Impact: T2 relaxation time mapping is critically investigated for addressing several MSK related diagnosis, but possibly due to thin and sensitive structures in the femoral head even slightest of the perturbations can lead to ineffective computation of quantitative mapping.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 60%
Phonocardiography and Auscultation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.