A Multi-Directional 4D PCMR Flow Phantom: Design and Experiments

Motivation: Accurate blood flow measurement is vital for the diagnosis of cardiovascular disorders. Existing phantoms focus primarily on validating flow using phase-contrast MR (PCMR) techniques along the three orthogonal directions. No phantom has been reported for the validation of flow in non-orthogonal orientations. Goal(s): To validate flow quantification accuracy on a phantom in non-orthogonal directions using 4D flow MRI. Approach: A multi-directional plexiglass phantom was designed and fabricated to evaluate accuracy of 4D flow PCMR using blood-mimicking flows within tubing controlled by a programmable pump. Results: The phantom was successfully used to validate flow in orthogonal and non-orthogonal directions simultaneously with 4D flow MRI. Impact: The flow phantom can be used to validate flow in 5 directions simultaneously with 4D flow MRI. The phantom has the potential to be used to optimize and standardize the 4D flow MR protocol parameters for clinical applications.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4771
Primary Topic
Aerodynamics and Acoustics in Jet Flows
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Multi-Directional 4D PCMR Flow Phantom: Design and Experiments

Enamul Bhuiyan, Guangyu Dan, Lauren Ostergren, Xiaohong Joe Zhou et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Aerodynamics and Acoustics in Jet Flows
article

A Multi-Directional 4D PCMR Flow Phantom: Design and Experiments

Enamul Bhuiyan, Guangyu Dan, Lauren Ostergren, Xiaohong Joe Zhou, Muge Karaman, Fady T. Charbel, Kezhou Wang, Qingfei Luo, Taylor Otey
article en

Abstract

Motivation: Accurate blood flow measurement is vital for the diagnosis of cardiovascular disorders. Existing phantoms focus primarily on validating flow using phase-contrast MR (PCMR) techniques along the three orthogonal directions. No phantom has been reported for the validation of flow in non-orthogonal orientations. Goal(s): To validate flow quantification accuracy on a phantom in non-orthogonal directions using 4D flow MRI. Approach: A multi-directional plexiglass phantom was designed and fabricated to evaluate accuracy of 4D flow PCMR using blood-mimicking flows within tubing controlled by a programmable pump. Results: The phantom was successfully used to validate flow in orthogonal and non-orthogonal directions simultaneously with 4D flow MRI. Impact: The flow phantom can be used to validate flow in 5 directions simultaneously with 4D flow MRI. The phantom has the potential to be used to optimize and standardize the 4D flow MR protocol parameters for clinical applications.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Good health and well-being
Openalex Percentile: Top 66%
Aerodynamics and Acoustics in Jet Flows
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.