MR-ARFI for transcranial ultrasound neuromodulation: The effect of varying frequency and depth.

Motivation: Previous MR-ARFI optimizations have incorporated tissue response times, but assumed those were constant in a homogenous medium. Goal(s): To demonstrate that tissue response times vary with ultrasound parameters such as frequency and depth, and to use those to optimize MR-ARFI. Approach: We measured displacement response time in a tissue-mimicking phantom at 0.5MHz and 1.0MHz ultrasound frequencies and depths of 40- and 60-mm. Results: With our tissue-mimicking phantom, the time constants were approximately 3ms and 6ms for 1.0MHz and 0.5MHz ultrasound frequencies, respectively. Impact: Ultrasound parameters of frequency and depth affect tissue response and can be used to optimize the acquisition to maximize SNR and minimize ultrasound dose.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2712
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MR-ARFI for transcranial ultrasound neuromodulation: The effect of varying frequency and depth.

Gary H. Glover, Morteza Mohammadjavadi, Kim Pauly
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Ultrasound and Hyperthermia Applications
article

MR-ARFI for transcranial ultrasound neuromodulation: The effect of varying frequency and depth.

Gary H. Glover, Morteza Mohammadjavadi, Kim Pauly
article en

Abstract

Motivation: Previous MR-ARFI optimizations have incorporated tissue response times, but assumed those were constant in a homogenous medium. Goal(s): To demonstrate that tissue response times vary with ultrasound parameters such as frequency and depth, and to use those to optimize MR-ARFI. Approach: We measured displacement response time in a tissue-mimicking phantom at 0.5MHz and 1.0MHz ultrasound frequencies and depths of 40- and 60-mm. Results: With our tissue-mimicking phantom, the time constants were approximately 3ms and 6ms for 1.0MHz and 0.5MHz ultrasound frequencies, respectively. Impact: Ultrasound parameters of frequency and depth affect tissue response and can be used to optimize the acquisition to maximize SNR and minimize ultrasound dose.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 80%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

MR-ARFI for transcranial ultrasound neuromodulation: The effect of varying frequency and depth. — Gary H. Glover, Morteza Mohammadjavadi, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS