Validation of mDixonQuant and IntelliSpace Portal for Liver Iron Estimation

Motivation: Simultaneous estimation of fat, water, and iron concentrations by MRI are now available on all three major MRI vendors, but the predicted liver iron concentration (LIC) values are sparsely validated. Goal(s): To cross validate LIC estimates generated by Philips mDixonQuant and IntelliSpace Portal (ISP) against LIC values measured by biopsy-validated, reference R2* and R2 methodsApproach: 51 subjects underwent MRI for clinical purposes, with collection of mDixonQuant, standard multiple-echo gradient echo, and Ferriscan R2 images. Results: R2* values generated by the default mDixonQuant and ISP packages yielded accurate LIC estimates using the Garbowski calibration for LIC < 25 mg/g. Impact: This work allows mDixonQuant and ISP to be used with confidence in the clinical setting to quantify liver siderosis in most subjects referred for iron quantification.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4762
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of mDixonQuant and IntelliSpace Portal for Liver Iron Estimation

Pedro Luiz Coelho Rodrigues, John C. Wood, Eamon Doyle, Johannes Peeters
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Nuclear Physics and Applications
article

Validation of mDixonQuant and IntelliSpace Portal for Liver Iron Estimation

Pedro Luiz Coelho Rodrigues, John C. Wood, Eamon Doyle, Johannes Peeters
article en

Abstract

Motivation: Simultaneous estimation of fat, water, and iron concentrations by MRI are now available on all three major MRI vendors, but the predicted liver iron concentration (LIC) values are sparsely validated. Goal(s): To cross validate LIC estimates generated by Philips mDixonQuant and IntelliSpace Portal (ISP) against LIC values measured by biopsy-validated, reference R2* and R2 methodsApproach: 51 subjects underwent MRI for clinical purposes, with collection of mDixonQuant, standard multiple-echo gradient echo, and Ferriscan R2 images. Results: R2* values generated by the default mDixonQuant and ISP packages yielded accurate LIC estimates using the Garbowski calibration for LIC < 25 mg/g. Impact: This work allows mDixonQuant and ISP to be used with confidence in the clinical setting to quantify liver siderosis in most subjects referred for iron quantification.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 70%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.