Bilateral Orthogonality Generating Acquisitions Method for Homogenous Balanced Steady-State Free Precession at 7T

Motivation: Elimination of the transmit field inhomogeneity effects in the brain for T2 contrast at 7T. Goal(s): Removing the transmit field inhomogeneity effects in balanced steady state free precession acquisitions using Bilateral Orthogonality Generative Acquisitions method. Approach: Bilateral Orthogonality Generative Acquisitions method is implemented at dual channel parallel transmit 7T system using several balanced steady state free precession acquisitions with varying scan parameters to eliminate the transmit field inhomogeneity effects and reduce the banding artifacts effects via different combining schemes in the final image. Results: T2 contrast was obtained without the transmit field inhomogeneity effects but residual banding artifacts exists in the final images. Impact: T2 contrast can be achieved without the transmit field inhomogeneity effects in the brain using balanced steady state free precession sequence.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4896
Primary Topic
Matrix Theory and Algorithms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bilateral Orthogonality Generating Acquisitions Method for Homogenous Balanced Steady-State Free Precession at 7T

A Henning, Çelik Boğa
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Matrix Theory and Algorithms
article

Bilateral Orthogonality Generating Acquisitions Method for Homogenous Balanced Steady-State Free Precession at 7T

A Henning, Çelik Boğa
article en

Abstract

Motivation: Elimination of the transmit field inhomogeneity effects in the brain for T2 contrast at 7T. Goal(s): Removing the transmit field inhomogeneity effects in balanced steady state free precession acquisitions using Bilateral Orthogonality Generative Acquisitions method. Approach: Bilateral Orthogonality Generative Acquisitions method is implemented at dual channel parallel transmit 7T system using several balanced steady state free precession acquisitions with varying scan parameters to eliminate the transmit field inhomogeneity effects and reduce the banding artifacts effects via different combining schemes in the final image. Results: T2 contrast was obtained without the transmit field inhomogeneity effects but residual banding artifacts exists in the final images. Impact: T2 contrast can be achieved without the transmit field inhomogeneity effects in the brain using balanced steady state free precession sequence.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 74%
Matrix Theory and Algorithms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.