Lactate Spectroscopic Imaging on a portable 46 mT Halbach MRI scanner

Motivation: Magnetic resonance spectroscopy at ultralow-field (B0 < 0.1T) on portable MRI scanner is challenging due to the low signal-to-noise ratio (SNR) and the impossible spectral separability. Goal(s): To obtain spectroscopic images of lactate at different concentrations in a phantom on our 46mT Halbach point-of-care MRI scanner and maximize SNR with incorporation of composite refocusing pulses. Approach: We modified a non-localized Carr-Purcell-Meiboom-Gill (CPMG) echo train sequence to perform 2D J-spectroscopic imaging in lactate phantom with composite refocusing pulses for improved SNR. Results: We showed the first steps towards lactate spectroscopic imaging at ultralow-field. Impact: The implementation of lactate spectroscopic imaging could add value to the growing list of biomedical applications of low field MR systems, for example in neonatal hypoxic ischemic encephalopathy.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2688
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lactate Spectroscopic Imaging on a portable 46 mT Halbach MRI scanner

Chloé Najac, Itamar Ronen, Andrew Webb
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Lactate Spectroscopic Imaging on a portable 46 mT Halbach MRI scanner

Chloé Najac, Itamar Ronen, Andrew Webb
article en

Abstract

Motivation: Magnetic resonance spectroscopy at ultralow-field (B0 < 0.1T) on portable MRI scanner is challenging due to the low signal-to-noise ratio (SNR) and the impossible spectral separability. Goal(s): To obtain spectroscopic images of lactate at different concentrations in a phantom on our 46mT Halbach point-of-care MRI scanner and maximize SNR with incorporation of composite refocusing pulses. Approach: We modified a non-localized Carr-Purcell-Meiboom-Gill (CPMG) echo train sequence to perform 2D J-spectroscopic imaging in lactate phantom with composite refocusing pulses for improved SNR. Results: We showed the first steps towards lactate spectroscopic imaging at ultralow-field. Impact: The implementation of lactate spectroscopic imaging could add value to the growing list of biomedical applications of low field MR systems, for example in neonatal hypoxic ischemic encephalopathy.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.