Multi-contrast Multi-resolution UTE for Myelin Fraction Mapping

Motivation: The direct detection of myelin is not possible due to extremely short T2 of the myelin bilayer. Ultra-short T2* component can be calculated with ultra-short echo-time (UTE) sequences. Goal(s): To evaluate the performance of the multi-contrast multi-resolution 3D-UTE sequence (mcUTE) in myelin fraction estimation. Approach: Combining 1-1 binomial water-excitation pulses and zero-moment encoding in between, mcUTE enables simultaneous acquisition of quantitative and high-resolution water-excited structural images. Myelin fraction from mcUTE is compared to myelin water fraction method. Results: Myelin fraction values were comparable with literature, and consistent within the subjects. Impact: mcUTE can potentially be used as a single imaging modality for myelin fraction estimation since it produces both quantitative and a high resolution water-excited anatomical image data in 18mins with TE=20μs. Our results show the acquisition can be further accelerated.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4588
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-contrast Multi-resolution UTE for Myelin Fraction Mapping

Uzay E. Emir, Shuai Liu, Serhat İlbey, Michael Bock et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Multi-contrast Multi-resolution UTE for Myelin Fraction Mapping

Uzay E. Emir, Shuai Liu, Serhat İlbey, Michael Bock, Marco Reisert, Ali Çağlar Özen, Alexander Rau, Nan Yin
article en

Abstract

Motivation: The direct detection of myelin is not possible due to extremely short T2 of the myelin bilayer. Ultra-short T2* component can be calculated with ultra-short echo-time (UTE) sequences. Goal(s): To evaluate the performance of the multi-contrast multi-resolution 3D-UTE sequence (mcUTE) in myelin fraction estimation. Approach: Combining 1-1 binomial water-excitation pulses and zero-moment encoding in between, mcUTE enables simultaneous acquisition of quantitative and high-resolution water-excited structural images. Myelin fraction from mcUTE is compared to myelin water fraction method. Results: Myelin fraction values were comparable with literature, and consistent within the subjects. Impact: mcUTE can potentially be used as a single imaging modality for myelin fraction estimation since it produces both quantitative and a high resolution water-excited anatomical image data in 18mins with TE=20μs. Our results show the acquisition can be further accelerated.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.