A 2-ch Wearable Elastic Adjustable Retunable (WEAR) Surface Coil at 3T with Broadband Matching
Motivation: Fixed-volume copper coils fail to accommodate volume changes and flexing of the imaging region, therefore spoil MR signal and hamper the diagnosis. Goal(s): To design a flexible surface coil for breast MR imaging. Approach: A 2-ch stretchable knitted textile coil and a 2-ch reference copper coil, which were compatible with three different sized phantoms were compared in terms of their sensitivity profiles and SNR results. Results: A three-stage broadband matching network could compensate for 15MHz of frequency shift. Although the textile coil was 31-81% more lossy compared to the copper coil, it only resulted in 10-26% SNR decrease. Impact: Despite loss of the WEAR coil, a textile-based coil can sustain a sample-loss-dominated behavior and a broadband matching network can compensate for the frequency shift without compromising on SNR.
Authors
- Korkut Yeğin (ORCID: https://orcid.org/0000-0002-0546-2832)
- Esin Öztürk-Işık (ORCID: https://orcid.org/0000-0002-8997-878X)
- Busra Kahraman-Agir
Publication Details
- Journal
- Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
- Published
- 2024-11-26
- DOI
- https://doi.org/10.58530/2024/1585
- Primary Topic
- Advanced Antenna and Metasurface Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00