Volumetric TSE-Based DWI Acquisition with a Pseudospiral K-Space Trajectory and Phase Correction Algorithm: Application in the Breast

Motivation: Current image quality limitations of conventional diffusion weighted sequences in the breast offer an exciting opportunity for novel acquisitions that can generate distortion-free images within clinically feasible scan times. Goal(s): To test a novel TSE-based 3D DWI sequence (VD-CASPR) in the breast of healthy volunteers and assess image quality with an incorporated phase correction algorithm. Approach: Four healthy volunteers were scanned with current reference standard DW-EPI and DW-TSE for breast serving as benchmark for our 3D DWI sequence. Results: Our VD-CASPR sequence with phase correction was able to generate high quality images at various b-values within shorter scan times compared to DW-TSE. Impact: Our novel 3D DWI sequence and reconstruction pipeline generated high SNR images free of geometric distortions in the breast of healthy volunteers. Volumetric coverage without geometric distortion can facilitate co-registration with anatomical images for improved tumor characterization.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4621
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Volumetric TSE-Based DWI Acquisition with a Pseudospiral K-Space Trajectory and Phase Correction Algorithm: Application in the Breast

Ananth J. Madhuranthakam, Sebastian Fonseca, Durga Udayakumar
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Photoacoustic and Ultrasonic Imaging
article

Volumetric TSE-Based DWI Acquisition with a Pseudospiral K-Space Trajectory and Phase Correction Algorithm: Application in the Breast

Ananth J. Madhuranthakam, Sebastian Fonseca, Durga Udayakumar
article en

Abstract

Motivation: Current image quality limitations of conventional diffusion weighted sequences in the breast offer an exciting opportunity for novel acquisitions that can generate distortion-free images within clinically feasible scan times. Goal(s): To test a novel TSE-based 3D DWI sequence (VD-CASPR) in the breast of healthy volunteers and assess image quality with an incorporated phase correction algorithm. Approach: Four healthy volunteers were scanned with current reference standard DW-EPI and DW-TSE for breast serving as benchmark for our 3D DWI sequence. Results: Our VD-CASPR sequence with phase correction was able to generate high quality images at various b-values within shorter scan times compared to DW-TSE. Impact: Our novel 3D DWI sequence and reconstruction pipeline generated high SNR images free of geometric distortions in the breast of healthy volunteers. Volumetric coverage without geometric distortion can facilitate co-registration with anatomical images for improved tumor characterization.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 80%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Volumetric TSE-Based DWI Acquisition with a Pseudospiral K-Space Trajectory and Phase Correction Algorithm: Application in the Breast — Ananth J. Madhuranthakam, Sebastian Fonseca, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS