Multi-Slice-Aware Denoising Model for 7T MR Angiography
Motivation: Noise in 7T MRA images can make it challenging to diagnose vascular diseases, and conventional denoisers tend to over-smooth in a way that blur entire image or does not preserve vascular information. Goal(s): Our goal was to reduce noise in 7T MRA images while maintaining vascular information using deep learning method. Approach: We devised an unsupervised denoising model using multiple slice information and cycleGAN-based neural networks. Results: Our approach not only suppressed noise in 7T MRA images, but it also successfully preserved vessel information among the compared models. Impact: We developed a denoising method in 7T MRA images while preserving vascular information. Clinically, our findings will help diagnose vascular-related diseases. High SNR is preserved by averaging adjacent slices, and we contribute to increase usability of 7T MRI.
Authors
- Byungjun Kim (ORCID: https://orcid.org/0000-0001-9925-9343)
- Sung‐Hye You (ORCID: https://orcid.org/0000-0001-5005-9383)
- Sang-Kwon Yun (ORCID: https://orcid.org/0000-0002-0374-9557)
- Hyunseok Seo (ORCID: https://orcid.org/0000-0003-0224-8942)
- Jeewon Kim
Publication Details
- Journal
- Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
- Published
- 2024-11-26
- DOI
- https://doi.org/10.58530/2024/1771
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00