Bias and Variability of Mean Diffusivity from DTI Across Two Head Coils: a Traceable Phantom Study

Motivation: Variability and bias of diffusion parameters need to be assessed to separate the measurement-induced variability from biological effects. Goal(s): Our goal was to assess the bias and variability of mean diffusivity (MD) from the Diffusion Tensor Model using a traceable phantom. Approach: The NIST/QIBA phantom was scanned multiple times using two different head coils on the same system. The differences between MD measured using different head coils and bias to NIST-reported values were investigated. Results: A significant difference in measured MD with two coils can be found across multiple vials. Both coils introduce non-negligible bias to NIST-reported values for lower MD values. Impact: Using traceable phantoms is essential in the development of Diffusion MRI-based Quantitative Imaging Biomarkers (QIBs). Different head coils can introduce significant differences across MD values and should be treated as confounding factors in QIBs studies.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4893
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bias and Variability of Mean Diffusivity from DTI Across Two Head Coils: a Traceable Phantom Study

Agnieszka Sierhej, Matt G. Hall, Nadia Smith, Chris Clark
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Thermography and Photoacoustic Techniques
article

Bias and Variability of Mean Diffusivity from DTI Across Two Head Coils: a Traceable Phantom Study

Agnieszka Sierhej, Matt G. Hall, Nadia Smith, Chris Clark
article en

Abstract

Motivation: Variability and bias of diffusion parameters need to be assessed to separate the measurement-induced variability from biological effects. Goal(s): Our goal was to assess the bias and variability of mean diffusivity (MD) from the Diffusion Tensor Model using a traceable phantom. Approach: The NIST/QIBA phantom was scanned multiple times using two different head coils on the same system. The differences between MD measured using different head coils and bias to NIST-reported values were investigated. Results: A significant difference in measured MD with two coils can be found across multiple vials. Both coils introduce non-negligible bias to NIST-reported values for lower MD values. Impact: Using traceable phantoms is essential in the development of Diffusion MRI-based Quantitative Imaging Biomarkers (QIBs). Different head coils can introduce significant differences across MD values and should be treated as confounding factors in QIBs studies.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 77%
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Bias and Variability of Mean Diffusivity from DTI Across Two Head Coils: a Traceable Phantom Study — Agnieszka Sierhej, Matt G. Hall, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS