Self-supervised learning with motion correction for fitting IVIM model parameters

Motivation: The existing fitting methods of lntravoxel incoherent motion (IVI M) parameter maps can already achieve good performance, but they all ignore the impact of internal heart beat or breathing movements on multiple b-value images for the fitting performance. Goal(s): We expect to incorporate motion correction in the fitting process to improve fitting performance. Approach: In this study, we propose an end-to-end deep network structure that combines self-supervised learning and motion correction for fitting IVIM parameters. Results: The quantitative and qualitative comparative experimental results indicate that using self-supervised motion correction can improve the fitting performance. Impact: For the first time, we consider incorporating motion correction into IVIM parameter fitting, and the self-supervised and end-to-end network design does not require training data, which can be extended to clinical applications.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2595
Primary Topic
Industrial Technology and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-supervised learning with motion correction for fitting IVIM model parameters

Baoer Liu, Yikai Xu, Zhou Wu, Feilin Deng
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Industrial Technology and Control Systems
article

Self-supervised learning with motion correction for fitting IVIM model parameters

Baoer Liu, Yikai Xu, Zhou Wu, Feilin Deng
article en

Abstract

Motivation: The existing fitting methods of lntravoxel incoherent motion (IVI M) parameter maps can already achieve good performance, but they all ignore the impact of internal heart beat or breathing movements on multiple b-value images for the fitting performance. Goal(s): We expect to incorporate motion correction in the fitting process to improve fitting performance. Approach: In this study, we propose an end-to-end deep network structure that combines self-supervised learning and motion correction for fitting IVIM parameters. Results: The quantitative and qualitative comparative experimental results indicate that using self-supervised motion correction can improve the fitting performance. Impact: For the first time, we consider incorporating motion correction into IVIM parameter fitting, and the self-supervised and end-to-end network design does not require training data, which can be extended to clinical applications.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 75%
Industrial Technology and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.