Improved Myelin Content Estimates from Clinical Selective Inversion Recovery Scans via Anisotropic Filtering

Motivation: Traditionally, Selective Inversion Recovery (SIR) images require long scan times for sufficient SNR, while shorter clinical scans yield low SNR images with noisy pool-size-Ratio (PSR) maps, leading to potential inaccuracies. Goal(s): An advanced filtering method has been used to improve the precision and accuracy of PSR maps from lower SNR scans. Approach: An advanced filtering method has been used to improve the precision and accuracy of PSR maps from lower SNR scans. Results: Initial results demonstrate that this method produces PSR maps comparable to longer, higher SNR scans from shorter clinical scans. Impact: The implementation of nonlinear anisotropic filtering methods significantly improves the practicality of SIR imaging in a clinical setting, offering quick, accurate myelin content assessments (without blurring tissue boundaries like linear filters) for applications in MS.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2508
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Myelin Content Estimates from Clinical Selective Inversion Recovery Scans via Anisotropic Filtering

Richard Dortch, Ashley M. Stokes, Mohammadreza Soltany Sadrabadi
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Improved Myelin Content Estimates from Clinical Selective Inversion Recovery Scans via Anisotropic Filtering

Richard Dortch, Ashley M. Stokes, Mohammadreza Soltany Sadrabadi
article en

Abstract

Motivation: Traditionally, Selective Inversion Recovery (SIR) images require long scan times for sufficient SNR, while shorter clinical scans yield low SNR images with noisy pool-size-Ratio (PSR) maps, leading to potential inaccuracies. Goal(s): An advanced filtering method has been used to improve the precision and accuracy of PSR maps from lower SNR scans. Approach: An advanced filtering method has been used to improve the precision and accuracy of PSR maps from lower SNR scans. Results: Initial results demonstrate that this method produces PSR maps comparable to longer, higher SNR scans from shorter clinical scans. Impact: The implementation of nonlinear anisotropic filtering methods significantly improves the practicality of SIR imaging in a clinical setting, offering quick, accurate myelin content assessments (without blurring tissue boundaries like linear filters) for applications in MS.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.