Design of a nonlinear human-breast gradient coil with controllable gradient variation

Motivation: To assess diffusion metrics on a cellular scale necessitates much higher gradient amplitudes. A local nonlinear breast gradient coil needs methods of controlling the field variation during the coil design stage. Goal(s): Control the y-axis gradient variation of a double layer local breast gradient coil to achieve far above 1T/m in the whole target region. Approach: Incorporation of a constraint to control the variation of the gradient along the y-axis with a double-layer current-carrying surface. Results: A non-linear local human breast gradient coil with a gradient strength between 1.61 and 3.74 T/m for a current of 650 A was designed. Impact: The coil design with a subsequent implementation paves the way to the application of novel diffusion imaging techniques for the detection and characterization of breast cancer.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4890
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a nonlinear human-breast gradient coil with controllable gradient variation

Philipp Amrein, Sebastian Littin, Maxim Zaitsev, Feng Jia
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Wireless Power Transfer Systems
article

Design of a nonlinear human-breast gradient coil with controllable gradient variation

Philipp Amrein, Sebastian Littin, Maxim Zaitsev, Feng Jia
article en

Abstract

Motivation: To assess diffusion metrics on a cellular scale necessitates much higher gradient amplitudes. A local nonlinear breast gradient coil needs methods of controlling the field variation during the coil design stage. Goal(s): Control the y-axis gradient variation of a double layer local breast gradient coil to achieve far above 1T/m in the whole target region. Approach: Incorporation of a constraint to control the variation of the gradient along the y-axis with a double-layer current-carrying surface. Results: A non-linear local human breast gradient coil with a gradient strength between 1.61 and 3.74 T/m for a current of 650 A was designed. Impact: The coil design with a subsequent implementation paves the way to the application of novel diffusion imaging techniques for the detection and characterization of breast cancer.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Good health and well-being
Openalex Percentile: Top 81%
Wireless Power Transfer Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design of a nonlinear human-breast gradient coil with controllable gradient variation — Philipp Amrein, Sebastian Littin, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS