T2* Relaxation Time Measurements of Various Brain Regions at 0.5 T

Motivation: Accurate knowledge of T2* relaxation times is important for optimizing contrast and SNR in multi-echo gradient echo sequences. Goal(s): To measure the nominal T2* relaxation parameter at 0.5 T over subregions in the brain. Approach: A 2 mm isotropic 3D multi-echo GRE sequence was acquired in 5 healthy volunteers. T2* estimates were computed over regions of interest using a mono-exponential fit. Results: T2* estimates of gray (86±8 ms) and white (78±5 ms) matter are in good agreement with previously published measurements in the mid-field. In the deep brain, average T2* values ranged between 70±2 ms to 89±5 ms. Impact: For optimal T2* contrast in the brain at 0.5 T, echoes from multi-echo acquisitions should extend beyond 60 ms. For optimal SNR, echoes should be combined with a target T2* of ~80 ms.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2683
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

T2* Relaxation Time Measurements of Various Brain Regions at 0.5 T

Blaine A. Chronik, Curtis N. Wiens, Andrea Soddu, Arjama Halder et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

T2* Relaxation Time Measurements of Various Brain Regions at 0.5 T

Blaine A. Chronik, Curtis N. Wiens, Andrea Soddu, Arjama Halder, Chad Harris
article en

Abstract

Motivation: Accurate knowledge of T2* relaxation times is important for optimizing contrast and SNR in multi-echo gradient echo sequences. Goal(s): To measure the nominal T2* relaxation parameter at 0.5 T over subregions in the brain. Approach: A 2 mm isotropic 3D multi-echo GRE sequence was acquired in 5 healthy volunteers. T2* estimates were computed over regions of interest using a mono-exponential fit. Results: T2* estimates of gray (86±8 ms) and white (78±5 ms) matter are in good agreement with previously published measurements in the mid-field. In the deep brain, average T2* values ranged between 70±2 ms to 89±5 ms. Impact: For optimal T2* contrast in the brain at 0.5 T, echoes from multi-echo acquisitions should extend beyond 60 ms. For optimal SNR, echoes should be combined with a target T2* of ~80 ms.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.