Spiral interleaving for diffusion encoding and relaxometry (SPIDER)

Motivation: Current diffusion readout methods have a relatively long echo time and readout duration, which prevent multi-echo imaging. Goal(s): To implement a diffusion sequence with multiple echoes readout for performing diffusion relaxometry. Approach: A 3-echo diffusion sequence, SPIDER, with variable density spiral readout was designed. Results: The proposed SPIDER showed comparable images with reference EPI method at shorter echo time. Impact: The proposed method showed the ability to acquire 3 echoes for 1mm2 resolution for low b-value, which could help multi-echo diffusion modeling.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2440
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spiral interleaving for diffusion encoding and relaxometry (SPIDER)

Yohan Jun, Yi Zhang, Hong‐Hsi Lee, Tao Zu et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced Neuroimaging Techniques and Applications
article

Spiral interleaving for diffusion encoding and relaxometry (SPIDER)

Yohan Jun, Yi Zhang, Hong‐Hsi Lee, Tao Zu, Shohei Fujita, Jaejin Cho, Berkin Bilgic̦, Xingwang Yong, Qiang Liu
article en

Abstract

Motivation: Current diffusion readout methods have a relatively long echo time and readout duration, which prevent multi-echo imaging. Goal(s): To implement a diffusion sequence with multiple echoes readout for performing diffusion relaxometry. Approach: A 3-echo diffusion sequence, SPIDER, with variable density spiral readout was designed. Results: The proposed SPIDER showed comparable images with reference EPI method at shorter echo time. Impact: The proposed method showed the ability to acquire 3 echoes for 1mm2 resolution for low b-value, which could help multi-echo diffusion modeling.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.