Feasibility of 3D Reduced-FOV Multi-shot Isotropic DWI in Optic Nerves

Motivation: Conventional 2D DWI sequences suffer from several disadvantages, therefore hindering the clinical visual assessment of optic nerves. Goal(s): This study aims to enable a 3D reduced-FOV multi-shot isotropic DWI sequence for optic nerves DWI and verify its feasibility. Approach: The pulse sequence and corresponding reconstruction algorithm of 3D reduced-FOV 2-shot isotropic DWI was developed to achieve effective and accurate reconstruction of optic nerves. Results: Preliminary results have shown the feasibility of our method in depicting the optic nerves with high resolution and high fidelity, therefore potentially benefiting the clinical applications of optic nerves DWI. Impact: 3D reduced-FOV multi-shot isotropic optic nerves DWI shows superior advantages of high resolution and high fidelity compared with other conventional DWI sequences, which should be further investigated and applied for clinical applications of optic nerves.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/1890
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of 3D Reduced-FOV Multi-shot Isotropic DWI in Optic Nerves

Hing‐Chiu Chang, Hailin Xiong, Liyuan Liang, Xiaorui Xu et al.
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Photoacoustic and Ultrasonic Imaging
article

Feasibility of 3D Reduced-FOV Multi-shot Isotropic DWI in Optic Nerves

Hing‐Chiu Chang, Hailin Xiong, Liyuan Liang, Xiaorui Xu, Tian Liu, Yi Li, Shihui Chen, Chenglang Yuan
article en

Abstract

Motivation: Conventional 2D DWI sequences suffer from several disadvantages, therefore hindering the clinical visual assessment of optic nerves. Goal(s): This study aims to enable a 3D reduced-FOV multi-shot isotropic DWI sequence for optic nerves DWI and verify its feasibility. Approach: The pulse sequence and corresponding reconstruction algorithm of 3D reduced-FOV 2-shot isotropic DWI was developed to achieve effective and accurate reconstruction of optic nerves. Results: Preliminary results have shown the feasibility of our method in depicting the optic nerves with high resolution and high fidelity, therefore potentially benefiting the clinical applications of optic nerves DWI. Impact: 3D reduced-FOV multi-shot isotropic optic nerves DWI shows superior advantages of high resolution and high fidelity compared with other conventional DWI sequences, which should be further investigated and applied for clinical applications of optic nerves.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 80%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.